• J Magn Reson Imaging · Sep 2013

    Comparative Study

    Diffusion-weighted imaging of the prostate: Comparison of b1000 and b2000 image sets for index lesion detection.

    • Andrew B Rosenkrantz, Nicole Hindman, Ruth P Lim, Kasturi Das, James S Babb, Thais C Mussi, and Samir S Taneja.
    • Department of Radiology, NYU Langone Medical Center, New York, NY 10016, USA. Andrew.Rosenkrantz@nyumc.org
    • J Magn Reson Imaging. 2013 Sep 1; 38 (3): 694-700.

    PurposeTo compare tumor detection on acquired diffusion-weighted (DW) images and apparent diffusion coefficient (ADC) maps, obtained using b-values of 1000 s/mm(2) and 2000 s/mm(2) , using radical prostatectomy as the reference.Materials And MethodsIn all, 29 prostate cancer patients who underwent 3T magnetic resonance imaging (MRI) including DW imaging using b-values of 1000 s/mm(2) and 2000 s/mm(2) were included. Two radiologists independently evaluated four image sets during different sessions and recorded the location and diameter of the dominant lesion: DW images acquired using b-values of 1000 s/mm(2) and 2000 s/mm(2) and ADC maps calculated using maximal b-values of 1000 s/mm(2) and 2000 s/mm(2) . Findings were correlated with the location and diameter of the dominant lesion at prostatectomy. Tumor-to-PZ contrast was also calculated, unblinded to pathology.ResultsBoth readers achieved significantly higher sensitivity for DW images obtained using a b-value of 2000 s/mm(2) than 1000 s/mm(2) (P < 0.001), although there was no difference in sensitivity between ADC maps calculated using the two b-values (P ≥ 0.309). Tumor-to-PZ contrast was higher for DW images using a b-value of 2000 s/mm(2) (P = 0.067), although it was not different between the two corresponding ADC maps (P = 0.544). For both readers, correlations with tumor diameters were higher for either ADC map (r = 0.59-0.73) than for either acquired DW image set (r = 0.03-0.57).ConclusionUse of a b-value of 2000 s/mm(2) compared with a b-value of 1000 s/mm(2) resulted in improved tumor sensitivity and higher tumor-to-PZ contrast on the acquired DW images, although performance of the ADC maps corresponding with the two b-values was similar. Correlation with tumor size was greater for either ADC map than for either acquired DW image set.Copyright © 2013 Wiley Periodicals, Inc., a Wiley company.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…