-
J Magn Reson Imaging · Sep 2013
Comparative StudyDiffusion-weighted imaging of the prostate: Comparison of b1000 and b2000 image sets for index lesion detection.
- Andrew B Rosenkrantz, Nicole Hindman, Ruth P Lim, Kasturi Das, James S Babb, Thais C Mussi, and Samir S Taneja.
- Department of Radiology, NYU Langone Medical Center, New York, NY 10016, USA. Andrew.Rosenkrantz@nyumc.org
- J Magn Reson Imaging. 2013 Sep 1; 38 (3): 694-700.
PurposeTo compare tumor detection on acquired diffusion-weighted (DW) images and apparent diffusion coefficient (ADC) maps, obtained using b-values of 1000 s/mm(2) and 2000 s/mm(2) , using radical prostatectomy as the reference.Materials And MethodsIn all, 29 prostate cancer patients who underwent 3T magnetic resonance imaging (MRI) including DW imaging using b-values of 1000 s/mm(2) and 2000 s/mm(2) were included. Two radiologists independently evaluated four image sets during different sessions and recorded the location and diameter of the dominant lesion: DW images acquired using b-values of 1000 s/mm(2) and 2000 s/mm(2) and ADC maps calculated using maximal b-values of 1000 s/mm(2) and 2000 s/mm(2) . Findings were correlated with the location and diameter of the dominant lesion at prostatectomy. Tumor-to-PZ contrast was also calculated, unblinded to pathology.ResultsBoth readers achieved significantly higher sensitivity for DW images obtained using a b-value of 2000 s/mm(2) than 1000 s/mm(2) (P < 0.001), although there was no difference in sensitivity between ADC maps calculated using the two b-values (P ≥ 0.309). Tumor-to-PZ contrast was higher for DW images using a b-value of 2000 s/mm(2) (P = 0.067), although it was not different between the two corresponding ADC maps (P = 0.544). For both readers, correlations with tumor diameters were higher for either ADC map (r = 0.59-0.73) than for either acquired DW image set (r = 0.03-0.57).ConclusionUse of a b-value of 2000 s/mm(2) compared with a b-value of 1000 s/mm(2) resulted in improved tumor sensitivity and higher tumor-to-PZ contrast on the acquired DW images, although performance of the ADC maps corresponding with the two b-values was similar. Correlation with tumor size was greater for either ADC map than for either acquired DW image set.Copyright © 2013 Wiley Periodicals, Inc., a Wiley company.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.