AJR Am J Roentgenol · Feb 2020
Evaluation of MRI Issues for a New Wirelessly Powered, Spinal Cord Stimulation Lead With Receiver.
- Laura P Vasquez, Ji Chen, and Frank G Shellock.
- Department of Medical Imaging Sciences, Rush University, College of Health Sciences, 600 S Paulina St, Ste 764AAC, Chicago, IL 60612.
- AJR Am J Roentgenol. 2020 Feb 1; 214 (2): 406-412.
AbstractOBJECTIVE. MRI is an imaging modality frequently ordered for patients with neuromodulation systems implanted for spinal cord stimulation. The purpose of this investigation was to evaluate MRI safety issues (magnetic field interactions, MRI-related heating, functional disturbances, and artifacts) for a new wirelessly powered lead with receiver used for SCS. MATERIALS AND METHODS. Lead samples underwent in vitro evaluation for MRI safety issues using standardized techniques. Magnetic field interactions (i.e., translational attraction and torque) and artifacts were tested at 3 T. MRI-related heating was performed at 1.5 T/64 MHz and 3 T/128 MHz using two different methods: numerical simulations with analytical modeling and physical testing. Possible functional disturbances were evaluated under exposures to 1.5-T/64-MHz and 3-T/128-MHz MRI conditions. RESULTS. The lead exhibited minor magnetic field interactions (22° deflection angle, no torque) at 3 T. The highest temperature change recorded at 1.5 T/64 MHz and 3 T/128 MHz was 3.8°C and 11.3°C, respectively. Exposures to MRI conditions did not damage or alter the functional aspects of the leads. The maximum artifact size seen on a gradient-echo pulse sequence extended approximately 10 mm relative to the size of the lead. CONCLUSION. The MRI tests performed on patients with the new lead with receiver revealed no substantial concerns with respect to the conditions that we provide in the safety guidelines that were based on the results of this investigation. Therefore, MRI examinations will result in acceptable heating when conducted at appropriate whole-body-averaged specific absorption rate levels (i.e., 2.0 W/kg at 1.5 T/64 MHz and 0.3 W/kg at 3 T/128 MHz, corresponding to adjusted temperature rises of 3.6°C and 1.2°C, respectively). Therefore, patients with this wirelessly powered lead and receiver implanted can safely undergo MRI examinations under specific conditions.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.