• AJR Am J Roentgenol · Oct 2009

    Comparative Study

    Radiation dose for body CT protocols: variability of scanners at one institution.

    • Tracy A Jaffe, Terry T Yoshizumi, Greta Toncheva, Colin Anderson-Evans, Carolyn Lowry, Chad M Miller, Rendon C Nelson, and Carl E Ravin.
    • Department of Radiology, Duke University Medical Center, Erwin Rd., Box 3808, Durham, NC 27710, USA. jaffe002@mc.duke.edu
    • AJR Am J Roentgenol. 2009 Oct 1; 193 (4): 1141-7.

    ObjectiveThe objective of our study was to determine, using an anthropomorphic phantom, whether patients are subject to variable radiation doses based on scanner assignment for common body CT studies.Materials And MethodsTwenty metal oxide semiconductor field effect transistor dosimeters were placed in a medium-sized anthropomorphic phantom of a man. Pulmonary embolism and chest, abdomen, and pelvis protocols were used to scan the phantom three times with GE Healthcare scanners in four configurations and one 64-MDCT Siemens Healthcare scanner. Organ doses were averaged, and effective doses were calculated with weighting factors.ResultsThe mean effective doses for the pulmonary embolism protocol ranged from 9.9 to 18.5 mSv and for the chest, abdomen, and pelvis protocol from 6.7 to 18.5 mSv. For the pulmonary embolism protocol, the mean effective dose from the Siemens Healthcare 64-MDCT scanner was significantly lower than that from the 16- and 64-MDCT GE Healthcare scanners (p < 0.001). The mean effective dose from the GE 4-MDCT scanner was significantly lower than that for the GE 16-MDCT scanner (p < 0.001) but not the GE 64-MDCT scanner (p = 0.02). For the chest, abdomen, and pelvis protocol, all mean effective doses from the GE scanners were significantly different from one another (p < 0.001), the lowest mean effective dose being found with use of a single-detector CT scanner and the highest with a 4-MDCT scanner. For the chest, abdomen, and pelvis protocols, the difference between the mean effective doses from the GE Healthcare and Siemens Healthcare 64-MDCT scanners was not statistically significant (p = 0.89).ConclusionAccording to phantom data, patients are subject to different radiation exposures for similar body CT protocols depending on scanner assignment. In general, doses are lowest with use of 64-MDCT scanners.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…