• J Magn Reson Imaging · Jun 2016

    Can intravoxel incoherent motion diffusion-weighted imaging characterize the cellular injury and microcirculation alteration in hepatic ischemia-reperfusion injury? An animal study.

    • Weitao Ye, Jinglei Li, Chengwei Guo, Shuting Chen, Yu-Bao Liu, Zaiyi Liu, Haijun Wu, Guangyi Wang, and Changhong Liang.
    • Department of Radiology, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong, P.R. China.
    • J Magn Reson Imaging. 2016 Jun 1; 43 (6): 1327-36.

    PurposeTo investigate whether intravoxel incoherent motion diffusion-weighted imaging (IVIM-DWI) can be used to quantitatively analyze the cellular injury and microcirculation alterations in hepatic ischemia-reperfusion injury (HIRI).Materials And MethodsThirty-two New Zealand white rabbits were randomly and equally assigned to the sham group, 1-hour, 4-hour, and 12-hour groups according to the reperfusion time after 1 hour of ischemia using a 70% liver ischemia-reperfusion injury model. All the animals underwent IVIM-DWI with 12 b values at 1.5T. The imaging parameters (IVIM parameters and apparent diffusion coefficient [ADC]) among different groups were compared. The correlations between imaging parameters and histological scores, and the ratio of serum aspartate aminotransferase to serum alanine aminotransferase (serum AST/ALT) were analyzed.ResultsDuring the first hour of HIRI, true diffusion coefficient (D) and ADC significantly decreased (P < 0.05), while there was no significant decrease in perfusion fraction (f) (P = 0.708). There was fair to good correlation between histological scores and f (rs  = -0.493 with the sham cases excluded, and -0.682 with all cases, both P < 0.05) and ADC (rs  = -0.479 with the sham cases excluded, and -0.766 with all cases, both P < 0.05). There was no correlation between imaging parameters and serum AST/ALT with the sham cases excluded (P = 0.673 for f, 0.568 for D, 0.403 for ADC), and good correlation between D, ADC, and serum AST/ALT (r = 0.747 and 0.748, both P < 0.001) with all cases.ConclusionIVIM-DWI can quantitatively characterize an animal model of HIRI, with D and ADC sensitive in early detection of cellular injury, as well as fair to good correlation between f, ADC, and microcirculation alteration. J. Magn. Reson. Imaging 2016;43:1327-1336.© 2015 Wiley Periodicals, Inc.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        

    hide…