• J Magn Reson Imaging · Dec 2013

    Comparative Study

    Free breathing three-dimensional gradient echo-sequence with radial data sampling (radial 3D-GRE) examination of the pancreas: Comparison with standard 3D-GRE volumetric interpolated breathhold examination (VIBE).

    • Saraporn Bamrungchart, Engy M Tantaway, Esin C Midia, Mateus A Hernandes, Saowanee Srirattanapong, Brian M Dale, and Richard C Semelka.
    • Department of Radiology, University of North Carolina at Chapel Hill, North Carolina, USA; Department of Radiology, Lerdsin hospital, Bangkok, Thailand.
    • J Magn Reson Imaging. 2013 Dec 1; 38 (6): 1572-7.

    PurposeTo evaluate the diagnostic performance of free breathing three-dimensional gradient echo-sequence with radial data sampling (radial 3D-GRE) in MR imaging of the normal and diseased pancreas, using standard 3D-GRE for comparison in cooperative patients, and to perform a preliminary assessment in noncooperative patients.Materials And MethodsOne hundred and eight consecutive patients underwent 1.5 Tesla MR imaging of the abdomen that included pre- and postcontrast free breathing radial 3D-GRE. The sequences were evaluated by two radiologists retrospectively, independently, and blindly. The results were compared using Wilcoxon-Mann-Whitney test. Kappa statistics were used to measure the extent of agreement between the reviewers.ResultsThe average scores indicated that the overall images quality of radial 3D-GRE was lower than 3D-GRE-VIBE in both pre- and postcontrast study (P = 0.0172 and 0.0001), however it achieved a rating that approximated good. In all patients, radial 3D-GRE had a mild extent of streak artifact, pulsation, susceptibility, and respiratory artifact. Radial 3D-GRE approximated good results for pancreatic edge sharpness and pancreatic ductal clarity, and did not differ significantly between cooperative and noncooperative patients. Respiratory artifact was worse in cooperative than in noncooperative patients (P = 0.02). Demonstration of pancreatic disease was slightly inferior with radial 3D-VIBE, but quality approximated good.ConclusionFree breathing radial 3D-GRE may be applicable for pancreatic MR imaging in patients who are unable to suspend respiration.Copyright © 2013 Wiley Periodicals, Inc.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…