• AJR Am J Roentgenol · Sep 1999

    Comparative Study

    Metallic stents: evaluation of MR imaging safety.

    • F G Shellock and V J Shellock.
    • Department of Radiology, School of Medicine, University of Southern California, Los Angeles 90036, USA.
    • AJR Am J Roentgenol. 1999 Sep 1; 173 (3): 543-7.

    ObjectiveThe objective of our investigation was to evaluate safety during MR imaging (i.e., magnetic field interactions, heating, and artifacts) for metallic stents.Materials And MethodsDifferent types of metallic stents were tested for magnetic field interactions, heating, and artifacts using a 1.5-T MR system. Magnetic field-related translational attraction and torque were assessed using previously described techniques. Heating was evaluated using an infrared thermometer to record temperatures immediately before and after performing MR imaging using a whole-body-averaged specific absorption rate of 1.3 W/kg. Artifacts were assessed by placing the stents inside a fluid-filled phantom and performing MR imaging using fast spoiled gradient-echo and T1-weighted spin-echo pulse sequences.ResultsFor the 10 different stents evaluated, we found no magnetic field interactions. the highest temperature change was < or = +0.3 degrees C, and the artifacts involved signal voids that would not create diagnostic problems as long as the area of interest was not positioned exactly where a particular stent was located.ConclusionThe findings of the safety tests indicated that the 10 different metallic stents would be safe for patients undergoing MR imaging procedures using MR systems with static magnetic fields of 1.5 T or less.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…