Effects of sample handling on total carbon dioxide concentrations in canine and feline serum and blood.
- K M James, D J Polzin, C A Osborne, and J K Olson.
- Department of Small Animal Clinical Sciences, College of Veterinary Medicine, University of Minnesota, St Paul 55108, USA.
- Am. J. Vet. Res. 1997 Apr 1; 58 (4): 343-7.
ObjectiveTo determine whether underfilling blood collection tubes leads to in vitro reduction in serum measured total CO2 concentration ([TCO2]m) in canine and feline blood samples sufficient to create the impression of metabolic acidosis (pseudometabolic acidosis) or high anion gap.Sample PopulationBlood samples from healthy client-owned animals (16 dogs, 17 cats).ProcedureVenous blood samples were collected in random order for determination of serum [TCO2] and blood gas tensions. Blood gas analysis was performed on iced, capped blood samples. In dogs, serum [TCO2] was measured in 1-, 3-, and 10-ml samples in 10-ml type-B tubes and in a 3-ml sample in 3-ml type-A tubes. In cats, serum [TCO2] was determined in 1-, 2-, and 3-ml samples in 3-ml type-A tubes and in a 3-ml sample in 10-ml type-B tubes.ResultsFor dogs, serum [TCO2] in full-tube, 10-ml samples was a mean +/- SD, 2.0 +/- 1.1 mmol/L greater than that in 3-ml samples and 3.7 +/- 1.3 mmol/L greater than the value in 1-ml samples; both differences were significant at P < 0.0001. The serum [TCO2] in full 3-ml samples was lower by 0.4 +/- 0.6 mmol/L than the value in full-tube 10-ml samples (P = 0.019). For cats, serum [TCO2] in full-tube, 3-ml samples was 0.5 +/- 0.6 mmol/L greater than that in 2-ml samples (P = 0.004) and was 1.5 +/- 0.8 mmol/L greater than the value in 1-ml samples (P < 0.0001). Serum [TCO2] in 3-ml samples of feline blood in 10-ml tubes was 0.8 +/- 0.8 mmol/L lower than that in samples from full 3-ml tubes (P = 0.0007). In dogs and cats, [TCO2] in fully filled collection tubes was approximately 6 mmol/L higher when calculated from blood gas analysis data than when chemically determined in serum.Conclusions And Clinical RelevanceUnderfilling blood collection tubes results in a false decrease in serum [TCO2], which can contribute in part to descrepancies between blood gas and chemical analyses as estimates of plasma bicarbonate concentration. This, and other in vitro effects of sample handling and collection, may result in a false assessment of metabolic acidosis in dogs and cats.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.