-
- N Martini, M F Santarelli, G Giovannetti, M Milanesi, D De Marchi, V Positano, and L Landini.
- Interdepartmental Research Center 'E. Piaggio', University of Pisa, Pisa, Italy. nicola.martini@ifc.cnr.it
- NMR Biomed. 2010 Jan 1; 23 (1): 66-73.
AbstractThe acquisition of magnetic resonance spectroscopy (MRS) signals by multiple receiver coils can improve the signal-to-noise ratio (SNR) or alternatively can reduce the scan time maintaining a reliable SNR. However, using phased array coils in MRS studies requires efficient data processing and data combination techniques in order to exploit the sensitivity improvement of the phased array coil acquisition method. This paper describes a novel method for the combination of MRS signals acquired by phased array coils, even in presence of correlated noise between the acquisition channels. In fact, although it has been shown that electric and magnetic coupling mechanisms produce correlated noise in the coils, previous algorithms developed for MRS data combination have ignored this effect. The proposed approach takes advantage of a noise decorrelation stage to maximize the SNR of the combined spectra. In particular Principal Component Analysis (PCA) was exploited to project the acquired spectra in a subspace where the noise vectors are orthogonal. In this subspace the SNR weighting method will provide the optimal overall SNR. Performance evaluation of the proposed method is carried out on simulated (1)H-MRS signals and experimental results are obtained on phantom (1)H-MR spectra using a commercially available 8-element phased array coil. Noise correlations between elements were generally low due to the optimal coil design, leading to a fair SNR gain (about 0.5%) in the center of the field of view (FOV). A greater SNR improvement was found in the peripheral FOV regions.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.