-
Arzneimittel Forsch · Jan 2009
Randomized Controlled TrialPharmacokinetics and bioequivalence study of escitalopram oxalate formulations after single-dose administration in healthy Chinese male volunteers.
- Jing Li, Yuan Tian, Zun-Jian Zhang, Na Wang, Xiaolei Ren, and Yun Chen.
- Key Laboratory of Drug Quality Control and Pharmacovigilance, China Pharmaceutical University, Ministry of Education, Nanjing, PR China.
- Arzneimittel Forsch. 2009 Jan 1; 59 (5): 228-32.
AbstractThe aim of the present study was to compare the bioavailability of escitalopram (CAS 128196-01-0) from two escitalopram oxalate (CAS 219861-08-2) tablets (escitalopram 10 mg tablet as test preparation and 10 mg tablet commercially available original tablet of the drug as reference preparation) in 20 Chinese healthy male volunteers, aged between 19 and 27. The study was conducted according to an open, randomized, single blind, 2-way crossover study design with a wash-out phase of 14 d. Blood samples for pharmacokinetic profiling were taken up to 156 h post-dose, and escitalopram plasma concentrations were determined with a validated liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS) method. Maximum plasma concentrations (C(max)) of 9.85 +/- 1.79 ng/ml (test) and 9.92 +/- 2.14 ng/ml (reference) were achieved. Areas under the plasma concentration-time curve (AUC(0-infinity)) of 428.40 +/- 140.25 ng x h/ml (test) and 413.73 +/- 144.81 ng x h/ml (reference), AUC(0-t) of 401.33 +/- 120.61 ng x h/ml (test), 385.42 +/- 117.73 ng x h/ml (reference) were calculated. The median T(max) was 4.3 +/- 1.8h, 4.1 +/- 1.5 h for test and reference formulation, respectively. Plasma elimination half-lives (t 1/2) of 36.30 +/- 8.93 h (test), 36.70 +/- 9.99 h (reference) were determined. Both primary target parameters, AUC(0-infinity) and AUC(0-t) were tested parametrically by analysis of variance (ANOVA) and relative bioavailabilities were 105.1 +/- 10.8% for AUC(0-infinity), 104.9 +/- 11.1% for AUC(0-t). Bioequivalence between test and reference preparation was demonstrated for both parameters, AUC(0-infinity) and AUC(0-t). The 90% confidence intervals of the T/R-ratios of logarithmically transformed data were in the generally accepted range of 80%-125%. That means that the test formulation is bioequivalent to the reference formulation for escitalopram.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.