• Med Phys · Apr 2018

    Effect of T1-mapping technique and diminished image resolution on quantification of infarct mass and its ability in predicting appropriate ICD therapy.

    • Nadia A Farrag, Venkat Ramanan, Graham A Wright, and Eranga Ukwatta.
    • Department of Systems and Computer Engineering, Carleton University, Ottawa, ON, K1S 5B6, Canada.
    • Med Phys. 2018 Apr 1; 45 (4): 1577-1585.

    PurposeMyocardial infarct (MI) may consist of an infarct core (IC) and a heterogeneous, semi-viable border zone (BZ). Patients with chronic MI in the left ventricular (LV) myocardium are at increased risk of developing ventricular arrhythmias, and may therefore qualify for implantable cardioverter defibrillator (ICD) therapy. Indices based on MI mass, as determined by cardiac magnetic resonance (CMR) imaging, are shown to be sensitive in predicting adverse ventricular arrhythmic events. However, several factors, such as imaging technique and spatial resolution affect the accuracy of MI mass quantification. The aim of this study was to compare the MI masses determined by T1-mapping CMR techniques to those of conventional late Gadolinium-enhanced cardiac magnetic resonance (LGE-CMR) using inversion recovery fast gradient echo (IR-FGRE). We additionally aimed to investigate the effect of diminishing image resolution on quantification of the MI mass and its ability to predict appropriate ICD therapy.MethodsThirty-eight patients with known MI underwent acquisitions of three CMR imaging techniques: the multicontrast late enhancement (MCLE) and modified look-locker inversion recovery (MOLLI) T1-mapping techniques, and conventional inversion recovery fast gradient echo (IR-FGRE) about 20 min after double-dose injection of Gadolinium. We postprocessed images to quantify IC and BZ masses determined by each CMR technique using a full-width half-maximum (FWHM) approach in IR-FGRE images and a fuzzy c-means clustering algorithm for T1-mapping images. To determine the impact of spatial resolution in sensitivity of predicting ICD events, we artificially diminished resolution of MCLE images acquired from a separate group of 27 patients who had been followed up for ICD therapy and compared the MI masses estimated from the original and downsampled MCLE images.ResultsTwelve patients out of 27 (44%) received ICD therapy (i.e., one or more delivered shock) during the follow-up stage. Between each of the three imaging methods, IC masses were not significantly different. Conversely, BZ masses determined by MOLLI were larger compared to those determined by MCLE and IR-FGRE (P value = 0.0022 and 0.0003, respectively). The BZ masses determined by MCLE were not significantly different from those determined by IR-FGRE; however, BZ masses determined by the downsampled MCLE were significantly larger than those determined by IR-FGRE and original MCLE (P value = 0.0033 and 0.0003, respectively). The BZ mass estimated by original MCLE was larger in patients who had received ICD therapy compared to those who did not (P value = 0.044). However, when the spatial resolution of the MCLE images was diminished to that of MOLLI, BZ masses were not significantly different between patients with and without ICD therapy.ConclusionsWhile estimated IC masses were consistent among all three techniques, the estimated BZ masses were not consistent, especially when spatial resolution of images differed between the techniques. In particular, our study showed that diminished image resolution caused an increase in estimation of the BZ mass, likely due to partial volume effects, which led to a reduced sensitivity in the prediction of appropriate ICD therapy.© 2018 American Association of Physicists in Medicine.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…