J Magn Reson Imaging · Feb 1999
A retrospective analysis of the accuracy of T2-weighted images and dynamic gadolinium-enhanced sequences in the detection and characterization of focal hepatic lesions.
- R S Pawluk, S Tummala, J J Brown, and J A Borrello.
- Mallinckrodt Institute of Radiology, Washington University Medical Center, St. Louis, Missouri 63110, USA.
- J Magn Reson Imaging. 1999 Feb 1; 9 (2): 266-73.
AbstractThe aim of this study was to determine the relative ability of T2-weighted and dynamic gadolinium-enhanced T1-weighted gradient-echo sequences to detect and characterize focal hepatic lesions. We retrospectively studied 37 patients with proven focal hepatic lesions using the following sequences: a T1-weighted spin-echo sequence (T1), a T2-weighted sequence (T2), and a series of breath-hold dynamic gadolinium-enhanced T1-weighted gradient-echo sequences (Gd). Two observers were asked to determine retrospectively the number and type of focal hepatic lesions present using images from three combinations of sequences (T1+T2, T1+Gd, T1+T2+Gd). Proof of the number and diagnosis of focal lesions in each patient was established using a consensus read. Both readers detected more focal lesions when both the T2-weighted sequences and the gadolinium-enhanced sequences were available than on either sequence alone, although this improvement reached statistical significance (P<0.05) only for one of the readers. There was no significant difference (P<0.05) in the ability to characterize lesions between any of the sets of sequences. The combination of dynamic gadolinium-enhanced images and T2-weighted images was shown to assess focal hepatic lesions better than either of these sequences alone.
Notes