• NMR in biomedicine · Oct 2007

    Standardized T2* map of normal human heart in vivo to correct T2* segmental artefacts.

    • Vincenzo Positano, Alessia Pepe, Maria Filomena Santarelli, Barbara Scattini, Daniele De Marchi, Anna Ramazzotti, Gianluca Forni, Caterina Borgna-Pignatti, Maria Eliana Lai, Massimo Midiri, Aurelio Maggio, Massimo Lombardi, and Luigi Landini.
    • MRI Laboratory, Institute of Clinical Physiology, CNR, Pisa, Italy. positano@ifc.cnr.it
    • NMR Biomed. 2007 Oct 1; 20 (6): 578-90.

    AbstractA segmental, multislice, multi-echo T2* MRI approach could be useful in heart iron-overloaded patients to account for heterogeneous iron distribution, demonstrated by histological studies. However, segmental T2* assessment in heart can be affected by the presence of geometrical and susceptibility artefacts, which can act on different segments in different ways. The aim of this study was to assess T2* value distribution in the left ventricle and to develop a correction procedure to compensate for artefactual variations in segmental analysis. MRI was performed in four groups of 22 subjects each: healthy subjects (I), controls (II) (thalassemia intermedia patients without iron overload), thalassemia major patients with mild (III) and heavy (IV) iron overload. Three short-axis views (basal, median, and apical) of the left ventricle were obtained and analyzed using custom-written, previously validated software. The myocardium was automatically segmented into a 16-segment standardized heart model, and the mean T2* value for each segment was calculated. Punctual distribution of T2* over the myocardium was assessed, and T2* inhomogeneity maps for the three slices were obtained. In group I, no significant variation in the mean T2* among slices was found. T2* showed a characteristic circumferential variation in all three slices. The effect of susceptibility differences induced by cardiac veins was evident, together with low-scale variations induced by geometrical artefacts. Using the mean segmental deviations as correction factors, an artefact correction map was developed and used to normalize segmental data. The correction procedure was validated on group II. Group IV showed no significant presence of segmental artefacts, confirming the hypothesis that susceptibility artefacts are additive in nature and become negligible for high levels of iron overload. Group III showed a greater variability with respect to normal subjects. The correction map failed to compensate for these variations if both additive and percentage-based corrections were applied. This may reinforce the hypothesis that true inhomogeneity in iron deposition exists.John Wiley & Sons, Ltd.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.