• Strahlenther Onkol · May 2008

    Multisegmented tangential breast fields: a rational way to treat breast cancer.

    • Akos Gulybán, Péter Kovács, Zsolt Sebestyén, Róbert Farkas, Tibor Csere, Gábor Karácsonyi, Katalin Dérczy, Katalin Hideghéty, and Olga Esik.
    • Department of Oncotherapy, University of Pécs, Hungary. akos.gulyban@gmail.com
    • Strahlenther Onkol. 2008 May 1; 184 (5): 262-9.

    PurposeUsing three-dimensional conformal radiation therapy (3D-CRT) and multisegmented conformal radiation therapy (MS-CRT) for breast cancer treatment, the dose coverage of the planning target volume (PTV) and the radiation burden on the organs at risk (OARs) were evaluated.Material And Methods3D-CRT and MS-CRT were planned for 436 unilateral breasts (217 left). All patients were treated with MS-CRT between 2005 and 2007. For PTV delineation and beam orientation, supportive structures were applied. The mean PTV was 1,130 cm3 (in ten patients > 2,200 cm3). Three-dimensional planning with weight-optimized medial and lateral open fields at a total dose of 50.4/1.8 Gy was followed by multisegmented planning with a reasonably high-dose-level dose cloud to define the medial subfield, and renewed optimization. This was repeated for the lateral subfield with a final optimization. For PTV coverage evaluation, the ICRU 50 was considered: the PTV portions receiving 95-107%, < 95% and > 107% of the prescribed dose (PTVD95- 107%, PTVD107%), and the PTV maximal dose (PTVDmax). To compare the OAR radiation burdens, the mean doses to the ipsi-/contralateral lung, contralateral breast, and whole heart were documented.ResultsThe multisegmented plans furnished significantly (p < 0.0001) better target coverage (PTVD95-107% 82.8% vs. 90.9%, PTVD107% 5.9% vs. 0.3% and PTVDmax 56.6 vs. 54.3 Gy). The mean OAR doses remained almost unchanged: ipsilateral lung 10.5 versus 10.4 Gy, contralateral lung 0.4 versus 0.4 Gy, contralateral breast 0.8 versus 0.8 Gy, and whole heart (for left-sided cancers) 4.8 versus 4.8 Gy. The subfields required a mean of 9.8 MU (monitor units), i.e., a mean total 7.6 MU increment. The planning took 10-20 min, and the delivery 5-10 min.ConclusionMS-CRT is a good alternative to breast intensity-modulated radiation therapy (IMRT) and seems adequate for right-sided cancers, whereas left-sided cancers necessitate a longer follow-up of heart-related side effects before a final assessment.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…