• Abdom Radiol (NY) · Jan 2016

    Comparative Study

    Readout-segmented echo-planar imaging in diffusion-weighted imaging of the kidney: comparison with single-shot echo-planar imaging in image quality.

    • Chen-Jiang Wu, Qing Wang, Jing Zhang, Xiao-Ning Wang, Xi-Sheng Liu, Yu-Dong Zhang, and Hai-Bin Shi.
    • Department of Radiology, The First Affiliated Hospital with Nanjing Medical University, No. 300, Guangzhou Road, Nanjing, 210000, China. njmu_wcj@163.com.
    • Abdom Radiol (NY). 2016 Jan 1; 41 (1): 100-8.

    ObjectiveThe purpose of this study was to compare the image quality of readout-segmented echo-planar imaging (RS-EPI) and that of standard single-shot echo-planar imaging (SS-EPI) in the kidney in a rat model.Materials And MethodsTwelve Wistar rats undergoing MRI examinations were imaged with two diffusion-weighted (DW) imaging protocols: a standard SS-EPI and a new RS-EPI protocol, both with a 1.0 × 1.0 × 3.0 mm voxel. The two groups of diffusion-weighted images were independently scored on geometric distortion, image blurring, signal dropout, and the overall image quality by two radiologists. Signal-to-noise ratio (SNR) and apparent diffusion coefficient (ADC) were measured on both sequences. Inter-rater agreement (IRA) was evaluated by Fleiss kappa (κ) and inter-class correlation coefficient (ICC) statistics. Comparisons of image qualities were made by Wilcoxon signed-rank test and paired-sample t test.ResultsBoth RS-EPI and SS-EPI had good IRAs in scoring image qualities (κ = 0.607-0.833) and measuring renal ADCs (ICC = 0.828-0.945). Compared to SS-EPI, RS-EPI produced less geometric distortion (median score 1.5 versus 2.5, p < 0.0001), less image blurring (1.75 versus 2.0, p = 0.0003), less signal dropout (1.0 versus 3.0, p = 0.0001), and a lower score in overall image artifacts (4.25 versus 7.25; p < 0.0001). RS-EPI had higher SNR of renal DW images than SS-EPI (p < 0.001). The intra-variability of ADCs in cortex, outer medulla, and inner medulla ranged from 9.6% to 11.1% (Pearson correlation coefficient ρ = 0.675-0.729; p < 0.001) between the two protocols.ConclusionWe showed that for DWI of the kidney at 1.0 × 1.0 × 3.0 mm(3) voxel sizes, the new protocol provided better image quality than standard SS-EPI protocol.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…