• Acta radiologica · Apr 2007

    The exactness of left ventricular segmentation in cine magnetic resonance imaging and its impact on systolic function values.

    • C Ebeling Barbier, L Johansson, L Lind, H Ahlström, and T Bjerner.
    • Department of Radiology, Uppsala University Hospital, Uppsala, Sweden. charlotte.ebeling_barbier@radiol.uu.se
    • Acta Radiol. 2007 Apr 1; 48 (3): 285-91.

    PurposeTo evaluate the impact of exactness of the segmentation of the left ventricle (LV), using cine magnetic resonance imaging (MRI).Material And MethodsSteady-state free-precession cine MRI was performed on 100 randomly selected subjects. Myocardial borders were outlined on short-axis images using three methods: method 1 was computer assisted, excluding papillary muscles from the left ventricular mass (LVM); method 2 was similar but included papillary muscles; and method 3 was manually traced including papillary muscles. LV end-systolic (ES) and end-diastolic (ED) masses and volumes, ejection fraction (EF), stroke volume (SV), and cardiac output (CO) were calculated from these measurements. The difference between the ES and ED LVM was used to estimate the exactness of the methods.ResultsMethod 3 was the most exact, and method 1 was the least exact. The three methods generated differing EF, SV, and CO measurements. With an ES-ED LVM difference exceeding 20 g, the mean SV measurement error was 8.8+/-3.6 ml.ConclusionManual tracing proved more exact than computer-assisted quantification. Exactness had an impact on EF, SV, and CO measurements, and the ES-ED LVM difference can be used to identify assessments that would benefit from more exact segmentation.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…