J. Clin. Microbiol. · Jul 2020
Evaluation of the QIAstat-Dx Respiratory SARS-CoV-2 Panel, the First Rapid Multiplex PCR Commercial Assay for SARS-CoV-2 Detection.
- Benoit Visseaux, Quentin Le Hingrat, Gilles Collin, Donia Bouzid, Samuel Lebourgeois, Diane Le Pluart, Laurène Deconinck, François-Xavier Lescure, Jean-Christophe Lucet, Lila Bouadma, Jean-François Timsit, Diane Descamps, Yazdan Yazdanpanah, Enrique Casalino, Nadhira Houhou-Fidouh, and Emergency Department Influenza Study Group.
- Université de Paris, Assistance Publique - Hôpitaux de Paris, Service de Virologie, Hôpital Bichat, Paris, France benoit.visseaux@aphp.fr.
- J. Clin. Microbiol. 2020 Jul 23; 58 (8).
AbstractIn the race to contain severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), efficient detection and triage of infected patients must rely on rapid and reliable testing. In this work, we performed the first evaluation of the QIAstat-Dx respiratory SARS-CoV-2 panel (QIAstat-SARS) for SARS-CoV-2 detection. This assay is the first rapid multiplex PCR (mPCR) assay, including SARS-CoV-2 detection, and is fully compatible with a non-PCR-trained laboratory or point-of-care (PoC) testing. This evaluation was performed using 69 primary clinical samples (66 nasopharyngeal swabs [NPS], 1 bronchoalveolar lavage fluid sample [BAL], 1 tracheal aspirate sample, and 1 bronchial aspirate sample) comparing SARS-CoV-2 detection with the currently WHO-recommended reverse transcription-PCR (RT-PCR) (WHO-RT-PCR) workflow. Additionally, a comparative limit of detection (LoD) assessment was performed for QIAstat-SARS and WHO-RT-PCR using a quantified clinical sample. Compatibility of sample pretreatment for viral neutralization or viscous samples with the QIAstat-SARS system were also tested. The QIAstat-Dx respiratory SARS-CoV-2 panel demonstrated a sensitivity comparable to that of the WHO-recommended assay with a limit of detection at 1,000 copies/ml. The overall percent agreement between QIAstat-Dx SARS and WHO-RT-PCR on 69 clinical samples was 97% with a sensitivity of 100% (40/40) and specificity at 93% (27/29). No cross-reaction was encountered for any other respiratory viruses or bacteria included in the panel. The QIAstat-SARS rapid multiplex PCR panel provides a highly sensitive, robust, and accurate assay for rapid detection of SARS-CoV-2. This assay allows rapid decisions even in non-PCR-trained laboratory or point-of-care testing, allowing innovative organization.Copyright © 2020 Visseaux et al.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.