• Clinical imaging · Sep 2018

    Comparative Study

    Comparing lesion detection of infratentorial multiple sclerosis lesions between T2-weighted spin-echo, 2D-FLAIR, and 3D-FLAIR sequences.

    • Kevin Y Wang, Tomas A Uribe, and Christie M Lincoln.
    • Department of Radiology, Baylor College of Medicine, Houston, TX, United States. Electronic address: yuqiw@bcm.edu.
    • Clin Imaging. 2018 Sep 1; 51: 229-234.

    PurposeInfratentorial lesions in patients with multiple sclerosis are associated with long-term disability. Two-dimensional fluid-attenuated inversion recovery demonstrates poor infratentorial lesion detection when compared to T2-weighted spin echo. Evidence of improved detection with 3D fluid-attenuated inversion recovery has been conflicting. This study compares the infratentorial lesion detection performance, observer performance, and signal and contrast properties between T2-weighted spin echo, 2D, and 3D fluid-attenuated inversion recovery.MethodsTwo board-certified radiologists independently reviewed and counted infratentorial lesions from 85 brain MRIs in patients with clinically definite multiple sclerosis and concurrent 3D, 2D fluid-attenuated inversion recovery, and T2-weighted spin echo sequences. Contrast-to-noise and signal-to-noise ratios were measured for 25 MRIs. Wilcoxon signed-rank test was used for pairwise comparisons of the combined average infratentorial lesion count, contrast-to-noise, and signal-to-noise ratios, and was adjusted for three pairwise comparisons using Bonferroni correction. A corrected p value < 0.05 was considered statistically significant.ResultsThe number of lesions on 3D fluid-attenuated inversion recovery was significantly higher than those on 2D (p < 0.001) and T2-weighted spin echo (p < 0.001). Results of contrast-to-noise and signal-to-noise ratios were overall mixed and predominantly not concordant with lesion count findings, with T2-weighted spin echo demonstrating the highest signal-to-noise ratios and contrast-to-noise ratio of lesion compared with white matter but the lowest contrast-to-noise ratio of lesion compared with gray matter.ConclusionThe 3D fluid-attenuated inversion recovery sequence addresses the disadvantage of poor infratentorial lesion detection on 2D, while still maintaining the advantage over T2-weighted spin echo in the detection of lesions adjacent to the cerebrospinal fluid.Copyright © 2018 Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…