    90-kVp low-tube-voltage CT pulmonary angiography in combination with advanced modeled iterative reconstruction algorithm: effects on radiation dose, image quality and diagnostic accuracy for the detection of pulmonary embolism.

    • Doris Leithner, Tatjana Gruber-Rouh, Martin Beeres, Julian L Wichmann, Scherwin Mahmoudi, Simon S Martin, Lukas Lenga, Moritz H Albrecht, Christian Booz, Thomas J Vogl, and Jan-Erik Scholtz.
    • 1 Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt , Frankfurt , Germany.
    • Br J Radiol. 2018 Jul 1; 91 (1088): 20180269.

    ObjectiveTo evaluate low-tube-voltage 90-kVp CT pulmonary angiography (CTPA) with advanced modeled iterative reconstruction algorithm (Admire) compared to 120-kVp equivalent dual-energy (DE) acquisition with regards to radiation exposure, image quality and diagnostic accuracy for pulmonary embolism (PE) assessment.MethodsCTPA studies of 40 patients with suspected PE (56.7 ± 16.3 years) performed on a third-generation 192-slice dual-source CT scanner were retrospectively included. 120-kVp equivalent linearly-blended (60% 90-kVp, 40% 150-kVp) and 90-kVp images were reconstructed. Attenuation and noise of the pulmonary trunk were measured to calculate contrast-to-noise ratios (CNR). Three radiologists assessed the presence of central and segmental PE and diagnostic confidence. Interobserver agreement was calculated using intraclass correlation coefficient (ICC). Radiation exposure was assessed as effective dose (ED).ResultsPulmonary trunk CNR values were significantly increased in 90-kVp compared to linearly-blended series (15.4 ± 6.3 vs 11.3 ± 4.6, p < 0.001). Diagnostic accuracy for PE assessment was similar in both series with excellent interobserver agreement (p = 0.48; ICC, 0.83; p = 0.48). Overall confidence for PE assessment was rated excellent for both series with a significant advantage for linearly-blended series (p < 0.001; 4.1 vs 3.8). ED was reduced by 37.2% with 90-kVp compared to 120-kVp equivalent image series (1.1 ± 0.6 vs 1.7 ± 0.7 mSv, p < 0.001).Conclusion90-kVp CTPA with Admire provided increased quantitative image quality with similar diagnostic accuracy and confidence for PE assessment compared to 120-kVp equivalent acquisition, while radiation dose was reduced by 37.2%. Advances in knowledge: 90-kVp CTPA with an advanced iterative reconstruction algorithm results in excellent image quality and reduction of radiation exposure without limiting diagnostic performance.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.