• J Vasc Access · Mar 2019

    Peripherally inserted central catheter with intracavitary electrocardiogram guidance: Malposition risk factors and indications for post-procedural control.

    • Céline Monard, Mathilde Lefèvre, Fabien Subtil, Vincent Piriou, and Jean-Stephane David.
    • 1 Département d'Anesthésie-Réanimation, Centre Hospitalier Lyon-Sud, Hospices Civils de Lyon, Lyon, France.
    • J Vasc Access. 2019 Mar 1; 20 (2): 128-133.

    Objectives:To confirm the feasibility of intracavitary electrocardiogram guidance to verify tip's position during insertion of peripherally inserted central catheter and to identify clinical factors or intracavitary electrocardiogram patterns associated with aberrant tip's position.Methods:A prospective study was conducted in our university hospital after authorization of the ethics committee. All patients addressed for peripherally inserted central catheter insertion were included and received the insertion using intracavitary electrocardiogram and electromagnetic guidance. Side of insertion and three electrocardiogram factors were collected: visualization of P-wave at baseline (sinusal rhythm), acquisition of the maximal P-wave and the negative deflection. All patients had a systematic post-procedural chest X-ray. One of the investigators assessed all chest X-ray, blinded to the results of intracavitary electrocardiogram, and confirmed whether the tip's position on chest X-ray matched with the intracavitary electrocardiogram information or if the tip was malpositioned on chest X-ray (mismatch with intracavitary electrocardiogram or aberrant position). Factors associated with malposition were described.Results:From January 2015 to April 2015, 330 patients were eligible, 5 had an uninterpretable chest X-ray, and 14 were non-sinusal at baseline. Our main analysis population included 311 patients. We observed a mismatch between intracavitary electrocardiogram and chest X-ray estimate of the tip's position in 3 cases (1%) and an aberrant tip's position occurred in 3 cases (1%). Incidence of malposition was higher in the group of patients with non-sinusal rhythm (14%) and when the catheter was inserted on the left side (7%).Conclusion:This study confirmed the feasibility of intracavitary electrocardiogram for peripherally inserted central catheter positioning and the limits of chest X-ray. Insertion on left side may represent risk factor for aberrant position but our study lacked power to establish a statistical link.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…