• Magn Reson Imaging · Apr 2018

    Effects of proximity and noise level of phased array coil elements on overall signal-to-noise in parallel MR spectroscopy.

    • Candace C Fleischer, Xiaodong Zhong, and Hui Mao.
    • Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA, United States.
    • Magn Reson Imaging. 2018 Apr 1; 47: 125-130.

    AbstractParallel imaging using phased array coils facilitates accelerated magnetic resonance imaging (MRI) and spectroscopy (MRS). Parallel data reconstruction requires the combination of data from individual coil elements, but limited combination algorithms currently exist for higher-order phased arrays and MRS data. Here, we present a systematic framework for identifying coil proximity-related signal inhomogeneities and noise levels in phased array coils that may affect sensitivity of parallel MRS. Single-voxel MRS was acquired in nine voxel positions in a brain spectroscopy phantom on a 3T whole-body MR scanner using commercially available 64-, 32-, and 20-channel phased array coils. Spectra produced by individual coil elements were combined using both a signal-to-noise ratio (SNR) threshold and based on the position of individual coil elements. SNR and metabolite Cramer-Rao lower bounds (CRLBs) from the final combined spectra were used as metrics to compare combination strategies and the effects of the phased array geometry and individual coil proximity. Comparisons were performed using one-way repeated measures ANOVA and post-hoc Tukey's range test (p<0.05). The 32-channel phased array coil produced the highest overall SNR compared to the 64-channel (p=0.0009) or 20-channel coils (p=0.003). Low SNR spectra from individual coil elements in the 64-channel coil can reduce the overall SNR when simply combining spectra from all elements. SNR varied significantly as a function of voxel position (F=58.3, p<0.0001) and SNR threshold for all phased arrays (p<0.05 for 64-, 32-, and 20-channel coils). Metabolite CRLBs were dependent on the combination strategy. We demonstrate the importance of the sampling voxel position and coil proximity on overall SNR in parallel MRS data acquisition, with significant SNR improvements after selectively filtering individual spectra based on pre-determined SNR thresholds which must be optimized for each phased array coil element and volume of interest.Copyright © 2017 Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,704,841 articles already indexed!

We guarantee your privacy. Your email address will not be shared.