Randomized Controlled Trial Multicenter Study
An abluminal biodegradable polymer sirolimus-eluting stent versus a durable polymer everolimus-eluting stent in patients undergoing coronary revascularization: 3-year clinical outcomes of a randomized non-inferiority trial.
- Haijun Zhang, Xiaoping Zhang, Yuxia Yin, Chao Zhou, Wei Deng, Junwei Zhang, Wenbo Hou, Shoutao Lu, Caixia Song, Xiaoshan Cui, Shenguo Wang, Fei Yang, Guang Liu, Cuihai Duan, and Junbo Ge.
- Intervention & Vascular Surgery, Medical College of Tongji University, Shanghai, China.
- Sci Rep. 2019 Dec 6; 9 (1): 18549.
AbstractThe Cordimax stent has proved non-inferior to the Cypher Select durable polymer sirolimus-eluting stent for the primary endpoint of angiographic in-stent late luminal loss and in-stent mean diameter stenosis at 9 months. The trial was designed to compare the efficacy and safety of the Cordimax stent with the Xience V stent in patients undergoing coronary revascularization. This randomized, multicenter trial enrolled 3697 patients treated with Cordimax stent (2460 patients) and Xience V stent (1237 patients). The primary efficacy endpoint was a target-lesion failure (TLF) at 1 year and the primary safety endpoint was a composite of death or myocardial infarction (MI) at 3 years. 3399 patients (91.9%) completed 3-year follow-up. At 1 year, the primary efficacy endpoint occurred in 86 (3.5%) patients in the Cordimax group versus 40 (3.2%) patients in the Xience V group (0.3% absolute risk difference, 95% CI -1.0-1.5%, Pnon-inferiority < 0.0001). At 3 years, the primary safety endpoint occurred in 39 (1.6%) patients in the Cordimax group versus 19 (1.5%) patients in the Xience V group (0.05% absolute risk difference, 95% CI -0.8-0.9%, Pnon-inferiority < 0.0001). The incidence of target lesion revascularization was low in Cordimax group compared with Xience V group (3.6% versus 5.1%, P = 0.03). There were no differences between Cordimax and Xience V in terms of Cardiac death (0.3% versus 0.4%, P = 0.70), myocardial infarction (1.2% versus 0.9%, P = 0.37), and the stent thrombosis (0.4% versus 0.6%, P = 0.61). In conclusion, safety and efficacy outcomes of Cordimax stent were non-inferior to the Xience V stent 3 years after stent implantation.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.