    Perforation holes in ventricular catheters--is less more?

    • Ulrich W Thomale, Henning Hosch, Arend Koch, Matthias Schulz, Giesela Stoltenburg, Ernst-Johannes Haberl, and Christian Sprung.
    • Pediatric Neurosurgery, Charité Universitätsmedizin Berlin, Berlin, Germany. uthomale@charite.de
    • Childs Nerv Syst. 2010 Jun 1; 26 (6): 781-9.

    ObjectiveObstruction is a common cause of cerebrospinal fluid (CSF) shunt failure. Risk factors for proximal obstructive malfunction are suboptimal ventricular catheter positioning and slit-like ventricles. A new ventricular catheter design to decrease risk of obstruction was evaluated.MethodsA review of histopathological tissue investigation from occluded ventricular catheters (n = 70) was performed. A new ventricular catheter design was realized with six perforation holes. These catheters were compared to regular catheters (16 holes, Miethke, Aesculap) for flow characteristics using ink studies and flow velocity at hydrostatic pressure levels from 14 to 2 cmH(2)O in an experimental setup. The six-hole catheters were implanted in hydrocephalic patients with slit-like ventricles (n = 55). A follow-up was performed to evaluate the need of catheter revisions.ResultsHistological evaluation showed that obstructive tissue involved 43-60% extraventricular tissue, including gliosis, connective and inflammatory cells. In flow characteristic studies, the 16-hole catheters showed that only proximal perforations are of functional relevance. For six-hole catheters, all perforations were shown to be relevant with remaining reserve capacity. Flow velocity however showed no significant differences between six and 16 perforations. The six-hole catheter was implanted in 55 patients with a mean follow-up period of 15 +/- 9 months. A total of 12 catheters were explanted, revealing an overall survival proportion of 77.4%.ConclusionIn narrow ventricles, we assume that catheter perforations that are located also in the tissue might be a risk for CSF shunt obstruction. Fewer amounts of perforations in the catheters with equal flow features might decrease this risk when catheters can be implanted with adequate precision.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.