Blood pressure monitoring · Apr 2012
Clinical TrialCan electronic sphygmomanometers be used for measurement of blood pressure at high altitudes?
- Shenshen Li, Xingshan Zhao, Sang Ba, Feng He, Christopher T Lam, Liang Ke, Nicole Li, Lijing L Yan, Xian Li, and Yangfeng Wu.
- The George Institute for Global Health, Beijing, China.
- Blood Press Monit. 2012 Apr 1; 17 (2): 62-8.
ObjectiveValidated automated oscillometric sphygmomanometers have been recommended by clinical guidelines to replace mercury sphygmomanometers. No studies have been conducted to evaluate whether these validated devices designed for use at normal altitude are also suitable at high altitudes.MethodsIn Dangxiong County in Tibet, 4300 m above sea level, two trained cardiologists used standardized protocols to measure the blood pressure (BP) of 129 adults aged between 19 and 69 years three times in a quiet room. The electronic sphygmomanometer was connected to the mercury sphygmomanometer by a 'Y,' or a three-way air-control valve, and the electronic device providing the pressure. This allowed simultaneous and blinded BP measurements with both instruments.ResultsThe mean systolic BP measured by the electronic sphygmomanometer (124.67 ± 20.39 mmHg) was significantly higher than the BP reported by the mercury device (118.91 ± 20.56 mmHg; P < 0.001), whereas the diastolic BP measured by electronic (76.54 ± 12.63 mmHg) and mercury (76.95 ± 13.86 mmHg) sphygmomanometers showed no significant difference (P = 0.228). There was a strong linear relationship between readings from the two instruments, with correlation coefficients for systolic and diastolic BP of 0.97 and 0.96, respectively. Bland-Altman plots showed a general consistency between the two instruments for both systolic and diastolic BP. The systolic BP values, calibrated by subtracting the mean difference, were not inferior to those obtained from linear regression equations.ConclusionThis first explorative study conducted at a high altitude demonstrated that the electronic sphygmomanometer can provide an accurate direct measurement of diastolic BP; however, a simple calibration is required for systolic BP.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.