J Magn Reson Imaging · Jul 2019
Accuracy and precision of proton density fat fraction measurement across field strengths and scan intervals: A phantom and human study.
- Hye Jin Kim, Hyo Jung Cho, Bohyun Kim, Myung-Won You, Jei Hee Lee, Jimi Huh, and Jai Keun Kim.
- Department of Radiology, Ajou University School of Medicine, Ajou University Hospital, Suwon, South Korea.
- J Magn Reson Imaging. 2019 Jul 1; 50 (1): 305-314.
BackgroundComplex-based chemical shift imaging-based magnetic resonance imaging (CSE-MRI) is emerging as a preferred method for noninvasively quantifying proton density fat fraction (PDFF), a promising quantitative imaging biomarker (QIB) for longitudinal hepatic steatosis measurement.PurposeTo determine linearity, bias, repeatability, and reproducibility of the PDFF measurement using CSE-MRI (CSE-PDFF) across scan intervals, MR field strengths, and readers in phantom and nonalcoholic fatty liver disease (NAFLD) patients.Study TypeInstitutional Review Board (IRB)-approved prospective.SubjectsFat-water phantom and 20 adult patients.Field Strength/Sequence1.5 T and 3.0 T MR systems and a commercially available CSE-MRI sequence (IDEAL-IQ).AssessmentTwo independent readers measured CSE-PDFF of fat-water phantom and NAFLD patients across two field strengths and scan intervals (same-day and 2-week) each and in a combination of both. MR spectroscopy-based PDFF (MRS-PDFF) was used as the reference standard for phantom PDFF.Statistical TestsLinearity and bias of measurement were evaluated by linear regression analysis and Bland-Altman plots, respectively. Repeatability and reproducibility were assessed by coefficient of variance and repeatability / reproducibility coefficients (RC). The intraclass correlation coefficient was used to validate intra- and interobserver agreements.ResultsCSE-PDFF showed high linearity and small bias (-0.6-0.4 PDFF%) with 95% limits of agreement within ±2.9 PDFF% across field strengths, 2-week interscan period, and readers in the clinical scans. CSE-PDFF was highly repeatable and reproducible both in phantom and clinical scans, with the largest observed RC across field strengths and 2-week interscan period being 3 PDFF%.Data ConclusionCSE-PDFF is a robust QIB with high linearity, small bias, and excellent repeatability/reproducibility. A change of more than 3 PDFF% across field strengths within 2 weeks of scan interval likely reflects a true change, which is well within the clinically acceptable range.Level Of Evidence3 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2019;50:305-314.© 2018 International Society for Magnetic Resonance in Medicine.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.