• Clinical biomechanics · Mar 2017

    Comparative Study

    Is pelvic fixation the only option to provide additional stability to the sacral anchorage in long lumbar instrumentation? A comparative biomechanical study of new techniques.

    • David Volkheimer, Heiko Reichel, Hans-Joachim Wilke, and Friederike Lattig.
    • Institute of Orthopedic Research and Biomechanics, Trauma Research Center Ulm (ZTF), Ulm University, Medical Center, Germany.
    • Clin Biomech (Bristol, Avon). 2017 Mar 1; 43: 34-39.

    BackgroundSupplementary iliac screws have the highest potential to protect S1-pedicle-screws from loosening in long fusion constructs. However, this technique bridges the iliosacral joint with potential disadvantages for the patient. This study aimed to evaluate if two different established fixation techniques can be used in addition to pedicle screws as alternative to iliac screws, and if these two techniques can provide similar stability when S1-pedicle-screws are loosened.MethodsFlexibility testing with pure moments of 7.5Nm was performed with six human osteopenic/osteoporotic L4-pelvis specimens. The following conditions were investigated: 1. Intact; 2. Destabilization L5/S1; 3. Fixation with rigid L4-S1 pedicle-screw-system; 4. Condition 3- loosening of S1-screws; 5. Condition 4- L5-S2-lamina-hooks; 6. Condition 4- L5/S1-translaminar-screws; 7. Condition 4- S2-ala-ilium screws.FindingsApplication of compressive L5-S2-lamina-hooks or L5/S1-translaminar-screws next to pedicle screws in L5 and S1 was feasible in all specimens. L4-S1-pedicle-screw-instrumentation reduced the Range of Motion significantly compared to the destabilized condition. After simulation of S1 screw loosening, lamina hooks only reduced the Range of Motion in flexion/extension significantly. L5/S1-translaminar-screws had a higher stabilizing effect in lateral bending and axial rotation, but the effect of both systems was smaller than with an instrumentation extension to the os ilium.InterpretationIn long lumbar pedicle screw instrumentations including L5/S1, additional ilium screws have the highest potential to protect the S1-anchorage. Additional L5/S1-translaminar-screws can increase stability of the lumbosacral junction without bridging the iliosacral joint, whereas lamina hooks showed no significant biomechanical benefit.Copyright © 2017 Elsevier Ltd. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…