Acta Orthop Traumatol Turc · Jan 2021
Interfragmentary lag screw and locking plate combination in simple distal femoral fractures: A finite element analysis.
- Jun Zhang, Yan Wei, Guoding Li, Jian Wang, and Youjia Xu.
- Department of Orthopaedics, The Second Affiliated Hospital of Soochow University, Suzhou, China;Department of Orthopaedics, Pudong New Area People's Hospital affiliated to Shanghai University of Medicine - Health Sciences, Shanghai, China.
- Acta Orthop Traumatol Turc. 2021 Jan 1; 55 (1): 9-15.
ObjectiveThe aim of this study was to evaluate the strength of the locking plate and lag screw construct that is applied in two different working lengths on the simple distal femur fracture model with a finite element analysis (FEA) method.MethodsFrom the computerized tomography scan data of a 60-year-old healthy male, the AO/OTA 33A1-type fracture model was simulated; the fracture gap was stabilized with the models of locking plate construct with (groups C and D) or without an interfragmentary lag screw (groups A and B). Furthermore, 102-mm plate (groups A and C) and 82-mm plate working lengths (groups B and D) were tested using FEA. Two loading conditions (axial compression and torsion) were applied at the center of the femoral head. Construct stiffness, interfragmentary micromotion, and the peak von Mises stress (VMS) on the plate were assessed.ResultsGroup D provided the highest axial stiffness (1347 N/mm), and group A was the weakest (439 N/mm). With the lag screw, shear micromotion remained generally low compared with that without the screw for all axial and torsional load levels and for both plate working lengths, i.e., 0.23 mm with lag screw versus 0.43 mm without lag screw (102 mm working length, 700 N). The percentage decreases of shear micromotion under axial (350/700/1400 N) and torsional loads for the 102-mm working length were >22% and 73%, respectively; while those for the 82-mm working length were >28% and 33%, respectively. The reduction of axial micromotion was observed with the lag screw for all axial load levels as well as for both plate working lengths, i.e., 0.33 mm with lag screw versus 0.87 mm without lag screw (102-mm working length, 700 N). The percentage decreases of axial micromotion under axial loading (350/700/1400 N) for 102 mm and 82 mm working lengths were >42% and 50%, respectively. The peak VMS on the plate stayed generally low with lag screw compared with without lag screw throughout all tested load levels, as well as for both plate working lengths, i.e., 124.26 MPa versus 244.39 MPa (102 mm working length, 700 N). The percentage decreases of the peak VMS under axial (350/700/1400 N) and torsional loads for the 102-mm working length were >40% and 69%, respectively, while those for the 82-mm working length were >47% and 61%, respectively.ConclusionThe current FEA concludes that in a simple distal femur fracture, adding a lag screw to a locking plate construct provides better torsional stability with a 102-mm plate working length and better axial stability with a 82-mm plate working length. Additionally, the strength of the materials is increased and implant failure can be minimized by using this technique.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.