    Accuracy of intravascular microcatheter pressure measurements: an experimental study.

    • H Henkes, S R Felber, K U Wentz, F Czerwinski, H Monstadt, W Weber, and D Kühne.
    • Department of Radiology and Neuroradiology, Alfried Krupp Krankenhaus, Essen, Germany.
    • Br J Radiol. 1999 May 1; 72 (857): 448-51.

    AbstractIntravascular pressure measurements are considered useful for the monitoring and assessment of endovascular treatment effects in intracranial vascular malformations. Experimental data on the accuracy of these measurements are limited. A flow phantom with defined intraluminal pressures and pulsatility flow waveforms was used in this study. Microcatheters commercially available for neuroendovascular procedures (length 140-155 cm), with different outer (0.5-0.83 mm) and inner (0.3-0.53 mm) diameters, were introduced into the phantom in the direction of flow. In a static experiment, pressure values from 0 to 75 mmHg were applied, and in the dynamic part of the experiment mean pressure values from 25 to 65 mmHg, with a pulsatile amplitude from 70 to 170 mmHg were employed. In the static experiment, there was a linear relationship between the pressure values obtained through the microcatheters and the local transducer of the flow phantom. The pulsatile experiments showed increased damping of the pressure waveforms with decreasing inner diameter of the microcatheters. However, the mean pressure values remained accurate. This experimental study has shown that mean pressure values can be accurately measured through microcatheters from 0.3-0.5 mm inner diameter and more than 140 cm in length. In vivo pressure measurements during interventional procedures are therefore reproducible and can be used for monitoring of embolization effects in patients.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…