• Plos One · Jan 2020

    The role of intraoperative microelectrode recording and stimulation in subthalamic lead placement for Parkinson's disease.

    • Vesna Malinova, Anabel Pinter, Cristina Dragaescu, Veit Rohde, Claudia Trenkwalder, Friederike Sixel-Döring, and Kajetan L von Eckardstein.
    • Department of Neurosurgery, Göttingen University Medical Center, Göttingen, Germany.
    • Plos One. 2020 Jan 1; 15 (11): e0241752.

    ObjectiveIntraoperative microelectrode recording (MER) and test-stimulation are regarded as the gold standard for proper placement of subthalamic (STN) deep brain stimulation (DBS) electrodes in Parkinson's disease (PD), requiring the patient to be awake during the procedure. In accordance with good clinical practice, most attending neurologists will request the clinically most efficacious trajectory for definite lead placement. However, the necessity of microelectrode-test-stimulation is disputed, as it may limit the access to DBS therapy, excluding those not willing or incapable of undergoing awake surgery.MethodsWe retrospectively analyzed the MERs and microelectrode-test-stimulation results with regard to the decision on definite lead placement and clinical outcome in a cohort of 67 PD-patients with STN-DBS. All patients received bilateral quadripolar ring electrodes. To ascertain overall procedural efficacy, we calculated the surgical index (SI) by comparing preoperative motor improvement induced by levodopa to that induced by stimulation 7 to 18 months after surgery, measured as the relative difference between ON and OFF-states on the Unified Parkinson's Disease Rating Scale motor part (UPDRS-3). Additionally, a side-specific surgical index (SSSI) was calculated using the unilateral assessable items of the UPDRS-3. The SSSI where microelectrode-test-stimulation overruled MER were compared to those where the result of microelectrode-test-stimulation was congruent to MER results.ResultsA total of 134 electrodes were analyzed. For final lead placement, the central trajectory was chosen in 54% of patient hemispheres. The mean SI was 0.99 (± 0.24). SSSI averaged 1.04 (± 0.45). In 37 lead placements, microelectrode-test-stimulation overruled MER in the final trajectory selection, in 27 of these lead placements adverse effects during microelectrode-test-stimulation were decisive. Neither the number of test electrodes used nor the STN-signal length had an impact on the SSSI. The SSSI did not differ between lead placements with MER/microelectrode-test-stimulation congruency and those where the results of microelectrode-test-stimulation initiated lead placement in a trajectory with shorter STN signal.ConclusionIntraoperative testing is mandatory to ensure an optimal motor outcome of STN DBS in PD-patients when using quadripolar ring electrodes. However, we also demonstrated that neither the length of the STN-signal on MER nor the number of test electrodes influenced the motor outcome.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…