• Chinese medical journal · Jan 2012

    Pure alumina bearings with cementless stems versus sandwich bearings with cemented stems in total hip arthroplasty.

    • Hao-Bo Wu, You-Zhi Cai, Zeng-Feng Xin, Xiang-Hua Wang, and Shi-Gui Yan.
    • Department of Orthopaedic Surgery, Second Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou, Zhejiang 310009, China.
    • Chin. Med. J. 2012 Jan 1; 125 (2): 244-8.

    BackgroundCeramic bearing surfaces have been introduced to prevent osteolysis after total hip arthroplasty (THA), but little is known about the difference in clinical and radiological results between pure alumina and sandwich alumina bearings. The purpose of this study was to analyze the results obtained with third-generation alumina-on-alumina THA with two different designs both in liner and femoral stem fixation after a minimum follow-up of 4.2 years.MethodsThe results of 195 primary alumina-on-alumina THAs in 167 patients were evaluated. The procedures were performed between January 1998 and October 2006. Three patients died and 11 patients were lost to follow-up, leaving a total of 153 patients (181 hips) available for study. In the 88 group A patients, 107 hips were implanted using pure alumina bearings with cementless femoral stems. These patients were followed for (6.84 ± 1.49) years. In the 65 group B patients, 74 hips were implanted using sandwich alumina ceramic bearings with cemented femoral stems. These patients had a follow-up period of (7.73 ± 1.60) years. Patients in both groups were evaluated clinically and radiographically.ResultsOne ceramic liner fracture occurred in group A and five took place in group B (P < 0.05), four of them revised for liner fracture. In each group, one acetabular shell migration happened without liner breakage and two hips developed deep infections, and all these six hips received revisions. Nine femoral components loosened in group B, with seven undergoing revisions. Kaplan-Meier survivorship at 5 years for revision of any component for any reason in group A was 96.26% compared to 90.54% in group B (P < 0.05). Better function was determined in group A (average Harris hip scores: 92.13 ± 2.85) than in group B (average Harris hip scores: 86.03 ± 4.21) and the difference was significant (P < 0.05). Squeaking was not recorded in either group.ConclusionsThe sandwich design of the acetabular bearings can not reduce the migration rate in ceramic bearings but increase the liner fracture rate compared to pure ceramic liners. The high loosening rate in fluted and taped designed cemented stems with sandwich liners warrant caution to their use.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…