• Zhonghua Jie He He Hu Xi Za Zhi · Jan 2016

    [The diagnostic utility of the Macao predictive values of impulse oscillometry for chronic obstructive pulmonary disease in patients over 45 years old].

    • X iaozhan Zhang, Zhenrong Zhang, Kun Cheng, Zhensheng Liang, Shuxin Lu, and Zhixuan Feng.
    • Department of Internal Medicine, Kiang Wu Hospital, Macao SAR, China.
    • Zhonghua Jie He He Hu Xi Za Zhi. 2016 Jan 1; 39 (1): 41-6.

    ObjectiveTo investigate the clinical use of Macao predictive values of impulse oscillometry(IOS) for chronic obstructive pulmonary disease (COPD) in patients aged over 45 years.MethodsWe measured lung impedance with IOS and spirometry in healthy subjects (n=168) and patients with COPD (n=281) aging over 45 years. The spirometric parameters were compared with those of IOS calculated by Macao predictive equations with Lechtenboerger equations.ResultsRespiratory impedance (Zrs), respiratory resistance at 5 Hz (R5), R5-R20 in female COPD group were (0.72±0.28), (0.63±0.23)and(0.23±0.16) kPa·L(-1)·s(-1), respectively, and Fres was (22±7)Hz; while in male group, the value of each parameters was (0.56±0.21), (0.50±0.17) and(0.18±0.12) kPa·L(-1)·s(-1), Fres was(21±7)Hz, which were all greater than that of the healthy group(t value was 5.05, 4.30, 5.10, 6.05 and 8.27, 6.62, 12.68, 14.59, respectively; P value were all<0.01). Reactance at 5 Hz(X5) in the COPD group[(-0.30±0.21) kPa·L(-1)·s(-1) in female, (-0.26±0.16) kPa·L(-1)·s(-1) in male] was significantly lower than that in the healthy group[female group: X5=(-0.16±0.06) kPa·L(-1)·s(-1,) t value was -5.38; male group: X5=(-0.10±0.05) kPa·L(-1)·s(-1,) t value was -11.96, P value were all<0.01]. Zrs, R5, R5-R20 and Fres were negatively correlated with parameters (FEV1/FVC, FEV1%Pre) of spirometry, while X5 was positively correlated with them. Compared with the ROC areas under the curve(AUC), the AUC of Zrs(A/P2) (0.786 in female, 0.773 in male) was same as that of Zrs(A)(0.744 in female, 0.764 in male; χ(2) value was 4.96, 0.89, respectively, P value were all >0.05), the AUC of R5(A/P2)(0.754 in female, 0.741 in male) was larger than that of R5(A/P1) (both were 0.716; χ(2) value was 4.24, 6.38, respectively, P value were all <0.05). The AUC of X5(P2-A) was larger than that of X5(P1-A) in the male group, and it was same as in the female group. The first two AUC of IOS parameters were Fres and R5-R20. In the 2 groups, when Zrs (A/P2)% was larger than 130, R5(A/P2)% was larger than 130, X5(P2-A)was larger than 0.1, Fres was larger than 15 in male, 20 in female, their each Youden's index was 0.463, 0.398, 0.662 and 0.594, each accuracy was 84%, 71%, 81% and 82%, which were all greater than that of Lechtenboerger equations(66%, 63%, 80% and 50%).ConclusionThere are good correlations between spirometry and respiratory impendance measured by IOS in the diagnosis of COPD. The Macao predictive equations have higher sensitivity and specificity for diagnosing COPD.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…