-
Interact Cardiovasc Thorac Surg · Mar 2020
Outcome of video-assisted thoracoscopic implantation of epicardial left ventricular leads with visual targeting for cardiac resynchronization therapy.
- Annina Stauber, Hildegard Tanner, Fabian Noti, Laurent Roten, Jens Seiler, Anna Lam, Argelia Medeiros-Domingo, Helge Servatius, Van Nam Tran, Thierry Carrel, and Alberto Weber.
- Department of Cardiology, Bern University Hospital, University of Bern, Bern, Switzerland.
- Interact Cardiovasc Thorac Surg. 2020 Mar 1; 30 (3): 373-379.
ObjectivesOur goal was to analyse the implantation and outcome of thoracoscopic epicardial leads after a failed endovascular approach or follow-up (FU) complications after endovascular implantation.MethodsWe reviewed the records of patients with failed endovascular left ventricular (LV) lead placement or complications during FU, who were subsequently referred to cardiac surgeons for treatment with thoracoscopic LV lead implantation. We analysed the reasons for endovascular failure; the indications for the surgical procedures; and the clinical, echocardiographic and device FU results.ResultsBetween 2010 and 2013, a total of 23 patients were included. Among them, 17 of the patients had no previous cardiothoracic surgery, 13 (76%) had successful video-assisted thoracoscopy (VAT) LV lead implantation, 3 (18%) had a conversion to thoracotomy and 1 (6%) failed. Of the 6 patients with prior cardiothoracic surgery, 2 (33%) had VAT only, 3 (50%) had primary thoracotomies and 1 (17%) had a conversion. Two major complications occurred. The reasons for LV endovascular lead failure were subclavian vein occlusion (n = 2), implant failure (n = 13) and complications during the FU period (n = 8). FU information was available for 20 patients: 17 (85%) had improved symptoms. The median FU period was 33 months. A total of 78% of patients were in New York Heart Association (NYHA) functional class III-IV before the operation; 30% were in NYHA functional class III-IV at the last FU examination. The left ventricular ejection fraction increased from 25% before surgery to 31% at the last FU examination. Overall, sensing and pacing threshold values remained stable over time. In 1 patient, lead revision was necessary due to an increase in the pacing threshold.ConclusionsVAT implantation of LV leads had an excellent response rate with an improvement in NYHA functional class and left ventricular ejection fraction. The lead measurements were mainly stable over time.© The Author(s) 2019. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.