Observational Study
Usefulness of Serial Multiorgan Point-of-Care Ultrasound in Acute Heart Failure: Results from a Prospective Observational Cohort.
- Marta Torres-Arrese, Gonzalo García de Casasola-Sánchez, Manuel Méndez-Bailón, Esther Montero-Hernández, Marta Cobo-Marcos, Mercedes Rivas-Lasarte, Luis Caurcel-Díaz, Pablo Rodríguez-Fuertes, Tomas Villén-Villegas, and Yale Tung-Chen.
- Department of Emergency Medicine, Hospital Universitario Fundación de Alcorcón, 28922 Madrid, Spain.
- Medicina (Kaunas). 2022 Jan 14; 58 (1).
AbstractBackground and Objectives: Acute heart failure (AHF) is a common disease and a cause of high morbidity and mortality, constituting a major health problem. The main purpose of this study was to determine the impact of multiorgan ultrasound in identifying pulmonary hypertension (PH), a major prognostic factor in patients admitted due to AHF, and assess whether there are significant changes in the venous excess ultrasonography (VE × US) score or femoral vein Doppler at discharge. Materials and Methods: Patients were evaluated with a standard protocol of lung ultrasound, echocardiography, inferior vena cava (IVC) and hepatic, portal, intra-renal and femoral vein Doppler flow patterns at admission and on the day of discharge. Results: Thirty patients were enrolled during November 2021. The mean age was seventy-nine years (Standard Deviation-SD 13.4). Seven patients (23.3%) had a worsening renal function during hospitalization. Regarding ultrasound findings, VE × US score was calculated at admission and at discharge, unexpectedly remaining unchanged or even worsened (21 patients, 70.0%). The area under the curve for the lung score was 83.9% (p = 0.008), obtaining a cutoff value of 10 that showed a sensitivity of 82.6% and a specificity of 71.4% in the identification of intermediate and high PH. It was possible to monitor significant changes between both exams on the lung score (16.5 vs. 9.3; p < 0.001), improvement in the hepatic vein Doppler pattern (2.4 vs. 2.1; p = 0.002), improvement in portal vein Doppler pattern (1.7 vs. 1.4; p = 0.023), without significant changes in the intra-renal vein Doppler pattern (1.70 vs. 1.57; p = 0.293), VE × US score (1.3 vs. 1.1; p = 0.501), femoral vein Doppler pattern (2.4 vs. 2.1; p = 0.161) and IVC collapsibility (2.0 vs. 2.1; p = 0.420). Conclusions: Our study results suggest that performing serial multiorgan Point-of-Care ultrasound can help us to better identify high and intermediate probability of PH patients with AHF. Currently proposed multi-organ, venous Doppler scanning protocols, such as the VE × US score, should be further studied before expanding its use in AHF patients.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.