Observational Study
Occupational dose and associated factors during transarterial chemoembolization of hepatocellular carcinoma using real-time dosimetry: A simple way to reduce radiation exposure.
- Hyoung Ook Kim, Byung Chan Lee, Chan Park, Jae Kyu Kim, Won-Ju Park, Jong Eun Lee, Hyo Soon Lim, and Won Gi Jeong.
- Department of Radiology, Chonnam National University Hwasun Hospital, Hwasun-gun, Jeollanam-do, Republic of Korea.
- Medicine (Baltimore). 2022 Jan 28; 101 (4): e28744e28744.
AbstractTransarterial chemoembolization is the standard treatment option for intermediate-stage hepatocellular carcinoma (HCC). However, during the interventional procedure, occupational radiation protection is compromised. The use of real-time radiation dosimetry could provide instantaneous radiation doses. This study aimed to evaluate the occupational dose of the medical staff using a real-time radiation dosimeter during transarterial chemoembolization (TACE) for HCC, and to investigate factors affecting the radiation exposure dose.This retrospective observational study included 70 patients (mean age: 66 years; age range: 38-88 years; male: female = 59: 11) who underwent TACE using real-time radiation dosimetry systems between August 2018 and February 2019. Radiation exposure doses of operators, assistants, and technicians were evaluated. Patients' clinical, imaging, and procedural information was analyzed.The mean dose-area product (DAP) and fluoroscopy time during TACE were 66.72 ± 55.14 Gycm2 and 12.03 ± 5.95 minutes, respectively. The mean radiation exposure doses were 24.8 ± 19.5, 2.0 ± 2.2, and 1.65 ± 2.0 μSv for operators, assistants, and technicians, respectively. The radiation exposure of the operators was significantly higher than that of the assistants or technicians (P < .001). The perpendicular position of the adjustable upper-body lead protector (AULP) on the table was one factor reducing in the radiation exposure of the assistants (P < .001) and technicians (P = .040). The DAP was a risk factor for the radiation exposure of the operators (P = .003) and technicians (P < .001).Occupational doses during TACE are affected by DAP and AULP positioning. Placing the AULP in the perpendicular position during fluoroscopy could be a simple and effective way to reduce the radiation exposure of the staff. As the occupational dose influencing factors vary by region or institution, further study is needed.Copyright © 2022 the Author(s). Published by Wolters Kluwer Health, Inc.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.