-
- Tyler S Cole, Sirin Gandhi, Joshua S Catapano, Vance L Fredrickson, Neil Majmundar, Felipe C Albuquerque, Andrew F Ducruet, Mark C Preul, and Michael T Lawton.
- Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona, USA.
- World Neurosurg. 2022 May 1; 161: e126-e133.
ObjectiveAlthough several commercially available sutureless anastomotic techniques are available, they are not routinely used in neurosurgery. We performed an in vivo flow analysis of end-to-end anastomosis using a microvascular coupler device in rats. We report our first clinical use of the microvascular anastomotic coupler.MethodsBilateral rat common carotid arteries (CCAs) were exposed, and a microvascular coupler was used to perform 8 anastomoses. A microflow probe provided quantitative measurement of blood-flow volume. Flow augmentation was assessed with end-to-side anastomoses connecting the distal CCA to the jugular vein (JV). A patient with chronic dominant hemisphere atherosclerotic ischemic disease and progressive symptoms refractory to medical management underwent end-to-end cerebral artery bypass using the microvascular coupler.ResultsMean preanastomosis flow in the rat CCA was 3.95 ± 0.45 mL/min; this flow was maintained at 3.99 ± 0.24 mL/min on final measurements 54-96 minutes postanastomosis. Total occlusion time for each rat CCA was 12-19 minutes. After end-to-side anastomosis, with proximal and distal JV patent, CCA flow increased 477% to 22.8 ± 3.70 mL/min (P = 0.04, proximal; P = 0.01, distal). After in vivo testing, we successfully used the coupler clinically in a superficial temporal artery-to-middle cerebral artery bypass for dominant hemisphere flow augmentation.ConclusionsIn vivo quantitative flow analysis demonstrated no flow difference between an unaltered artery and artery with end-to-end anastomosis using a microvascular coupler in rats. A 1-mm coupled anastomosis achieved a 4-fold flow increase with low-resistance venous outflow in rats, simulating increased arterial demand. The coupler was successfully used for extracranial-to-intracranial bypass in a patient.Copyright © 2022 Elsevier Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.