• World Neurosurg · May 2022

    In vivo preclinical quantitative flow analysis of arterial anastomosis using a microvascular anastomotic coupler and clinical application for extracranial-to-intracranial bypass.

    • Tyler S Cole, Sirin Gandhi, Joshua S Catapano, Vance L Fredrickson, Neil Majmundar, Felipe C Albuquerque, Andrew F Ducruet, Mark C Preul, and Michael T Lawton.
    • Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona, USA.
    • World Neurosurg. 2022 May 1; 161: e126-e133.

    ObjectiveAlthough several commercially available sutureless anastomotic techniques are available, they are not routinely used in neurosurgery. We performed an in vivo flow analysis of end-to-end anastomosis using a microvascular coupler device in rats. We report our first clinical use of the microvascular anastomotic coupler.MethodsBilateral rat common carotid arteries (CCAs) were exposed, and a microvascular coupler was used to perform 8 anastomoses. A microflow probe provided quantitative measurement of blood-flow volume. Flow augmentation was assessed with end-to-side anastomoses connecting the distal CCA to the jugular vein (JV). A patient with chronic dominant hemisphere atherosclerotic ischemic disease and progressive symptoms refractory to medical management underwent end-to-end cerebral artery bypass using the microvascular coupler.ResultsMean preanastomosis flow in the rat CCA was 3.95 ± 0.45 mL/min; this flow was maintained at 3.99 ± 0.24 mL/min on final measurements 54-96 minutes postanastomosis. Total occlusion time for each rat CCA was 12-19 minutes. After end-to-side anastomosis, with proximal and distal JV patent, CCA flow increased 477% to 22.8 ± 3.70 mL/min (P = 0.04, proximal; P = 0.01, distal). After in vivo testing, we successfully used the coupler clinically in a superficial temporal artery-to-middle cerebral artery bypass for dominant hemisphere flow augmentation.ConclusionsIn vivo quantitative flow analysis demonstrated no flow difference between an unaltered artery and artery with end-to-end anastomosis using a microvascular coupler in rats. A 1-mm coupled anastomosis achieved a 4-fold flow increase with low-resistance venous outflow in rats, simulating increased arterial demand. The coupler was successfully used for extracranial-to-intracranial bypass in a patient.Copyright © 2022 Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…