• Eur Heart J Acute Cardiovasc Care · Sep 2013

    Evaluation of the diagnostic performance of current and next-generation assays for cardiac troponin I in the BWH-TIMI ED Chest Pain Study.

    • Marc P Bonaca, Christian T Ruff, Joshua Kosowsky, Michael J Conrad, Sabina A Murphy, Marc S Sabatine, Petr Jarolim, and David A Morrow.
    • Harvard Medical School, Boston, MA, USA.
    • Eur Heart J Acute Cardiovasc Care. 2013 Sep 1;2(3):195-202.

    BackgroundRapid diagnosis of acute coronary syndrome is a clinical and operational priority in busy emergency departments (ED). We examined the performance of an investigational troponin I (TnI) assay with 10-100-times greater sensitivity than current commercial assays.MethodsAmong patients with non-traumatic chest pain enrolled in the BWH-TIMI ED Chest Pain Study, we measured TnI (n=381) at baseline, 4-6 h, and 12-24 h with an investigational assay (S-TnI; Singulex, detection-limit 0.0002 µg/l, 99th percentile 0.009 µg/l) and a contemporary sensitive assay (TnI-Ultra; Siemens, detection-limit 0.006 µg/l, 99th percentile 0.04 µg/l). Final diagnosis was adjudicated using all diagnostic data and local hospital-based cardiac TnI (Siemens), blinded to investigational cardiac Tn.ResultsThe adjudicated diagnosis was myocardial infarction (MI) in 96 patients, unstable angina in 41, and acute non-coronary cardiovascular conditions in 50 patients. Baseline S-TnI was highly sensitive for MI (97%, 95% CI 91-99%) with specificity 81% (95% CI 76-86%) and positive predictive value 63% (95% CI 55-71%). The negative predictive value with S-TnI was 99% (95% CI 96-100%). S-TnI had better diagnostic accuracy than the local assay (area under the curve 0.976 vs. 0.916, p=0.003). Among 20 patients with negative baseline TnI and diagnosis of MI, 19 had elevated baseline S-TnI. Compared to TnI-Ultra, S-TnI trended toward higher sensitivity (97 vs. 94%, p=NS) but did not differ significantly in negative predictive value (99 vs. 98%) or area under the curve (p=0.29).ConclusionCurrent and investigational Tn assays substantially increased clinical sensitivity and improved diagnostic accuracy for MI, despite a decline in specificity. A contemporary sensitive assay delivered similar overall accuracy to the investigational test, suggesting that we have reached a point of maximum diagnostic return with increasing analytical sensitivity.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…