    The effect of anterior-posterior shear on the wear of CHARITÉ total disc replacement.

    • Rachel Vicars, Polina Prokopovich, Thomas D Brown, Joanne L Tipper, Eileen Ingham, John Fisher, and Richard M Hall.
    • Institute of Medical and Biological Engineering, University of Leeds, UK.
    • Spine. 2012 Apr 20; 37 (9): E528-34.

    Study DesignAn in vitro study of the wear rates of the CHARITÉ lumbar total disc replacement (TDR).ObjectiveTo investigate the effect of anterior-posterior shear on the in vitro wear rates of the CHARITÉ lumbar TDR.Summary Of Background DataCurrent standards prescribe only 4-degrees of freedom (DOF) inputs for evaluating the in vitro wear of TDRs, despite the functional spinal unit incorporating 6 DOF. Anterior-posterior shear has been highlighted as a significant load, particularly in the lumbar spine. A previous study investigated the effect of an anterior-posterior shear on the ProDisc-L, finding that wear rates were not significantly different from 4-DOF wear tests.MethodsSix CHARITÉ lumbar discs were mounted in a 5 active DOF spine wear simulator and tested under 4-DOF (ISO18192) conditions. Six further CHARITÉ lumbar discs were tested under 5-DOF conditions, consisting of 4-DOF conditions plus an anterior-posterior shear displacement of +2/-1.5 mm. The displacement was decreased and then increased by a factor of 2 to investigate the effect of the magnitude of displacement. Micro-computed tomographic scans of the discs were taken before and after wear testing, and the height loss of the discs was calculated. These were compared with the same measurements taken from explanted CHARITÉ discs, micro-computed tomography scanned at another institution.ResultsWear rates for 4 DOF (12.2 ± 1.0 mg/MC) were not significantly different from 4-DOF tests on the ProDisc-L. Wear rates were significantly increased (P < 0.01) for "standard" 5-DOF conditions (22.3 ± 2.0 mg/MC), decreased 5 DOF (24.3 ± 4.9 mg/MC), and increased 5 DOF (29.1 ± 7.6 mg/MC). The height loss of the explants and in vitro tested discs were not significantly different (P > 0.05).ConclusionThe addition of anterior-posterior shear to wear testing inputs of the CHARITÉ lumbar TDR increases the wear rate significantly, which is in direct contrast to the previous 5-DOF testing on the ProDisc. This study highlights the importance of clinically relevant testing regimens, and that test inputs may be different for dissimilar design philosophies.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.