-
Chinese medical journal · Nov 2018
An innovative three-dimensional method for identifying a proper femoral intramedullary entry point in total knee arthroplasty.
- Lu-Yao Ma, Hong-Yu Wei, Fu-Yin Wan, Wan-Shou Guo, and Jin-Hui Ma.
- Department of Orthopaedics, Second Hospital of Shanxi Medical University, Taiyuan, Shanxi 030001, China.
- Chin. Med. J. 2018 Nov 5; 131 (21): 2531-2536.
Background:Identification of the proper femoral intramedullary (IM) access point is an important determinant of final implant position in IM-guided total knee arthroplasty (TKA). The aim of this study was to identify the optimal entry point in Chinese participants using a new three-dimensional method.Methods:A series of computed tomography scans of 44 femurs in Chinese participants from October 2014 to October 2015 were imported into Mimics 17.0 software to identify the optimal entry point. The apex of the intercondylar notch (AIN) was used as the reference bony anatomical landmark to identify the proper entry point to insert the IM rod. The statistical significance was calculated on the basis of a 5% level (P < 0.05) using the Student's t-test.Results:For the males, the average ideal entry point was 1.49 mm medial and 13.39 mm anterior to the AIN. The values were 1.77 mm medial and 15.29 mm anterior to the AIN in females. A significant difference was present between males and females (13.39 ± 2.46 mm vs. 15.29 ± 3.44 mm, t = 2.124, P = 0.040). When using the recommended location as the entry point for the IM rod, the mean potential error differed significantly from the femoral trochlear groove (the potential error of IM in males in coronal plane: 0.93° ± 0.24° vs. 1.27° ± 0.32°, t = -4.166, P <0.001; the potential error of IM in males in sagittal plane: 1.40° ± 0.42° vs. 2.79° ± 0.70°, t = 7.155, P < 0.001; the potential error of IM in females in coronal plane: 0.73° ± 0.28° vs. 1.15° ± 0.35°, t = 3.940, P < 0.001; and the potential error of IM in females in sagittal plane: 1.48° ± 0.47° vs. 2.76° ± 0.83°, t =5.574, P < 0.001). A significant difference was present between the recommended point and the point 10 mm anterior to the origin of the posterior cruciate ligament (the potential error of IM in males in coronal plane: 0.93° ± 0.24° vs. 1.53° ± 0.43°, t = 5.948, P < 0.001; the potential error of IM in males in sagittal plane: 1.40° ± 0.42° vs. 2.15° ± 0.75°, t = 3.152, P = 0.003; the potential error of IM in females in coronal plane: 0.73° ± 0.28° vs. 1.28° ± 0.42°, t = -4.632, P < 0.001; and the potential error of IM in females in sagittal plane: 1.48° ± 0.47° vs. 2.40° ± 0.93°, t = 3.763, P = 0.001).ConclusionsThe technique described here is an innovative method for swift, easy, and accurate access to the medullary canal during TKA, and it can optimize the position and orientation of the prosthetic components in knee arthroplasty.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.