-
- Edward Koźluk, Agnieszka Piątkowska, Dariusz Rodkiewicz, Michał Peller, Janusz Kochanowski, and Grzegorz Opolski.
- 1 Chair and Department of Cardiology, Medical University of Warsaw, Warsaw, Poland.
- Arch Med Sci. 2019 Jan 1; 15 (1): 78-85.
IntroductionOur aim was to compare in a prospective randomized study the safety, direct results and periprocedural data of ablation using an nMARQ catheter, a PVAC catheter used with the EnSite system, or a PVAC catheter only under fluoroscopy control.Material And MethodsOne hundred two patients (70 male, 57 ±11 years) with atrial fibrillation (AF) were prospectively randomized to: group 1 - ablation performed with an nMARQ catheter and the CARTO 3 system; group 2 - a PVAC catheter used with the EnSite system; group 3 - ablation with a PVAC catheter without a 3D system.ResultsComplete isolation of 400/402 pulmonary veins (PV) (99.5%). Linear ablation was performed in 23 patients in group 1 (small distance between lines isolating PV), in 3 patients in group 2, in 1 patient in group 3. The superior vena cava was isolated in 1 patient, 9 patients, and 9 patients respectively. Duration of fluoroscopy and dose area product were significantly smaller in group 1 (6.5 ±2.9 min/808.8 ±393.9 cGy/cm2 vs. 13.6 ±5.6 min/1662.6 ±677.8 cGy/cm2 and 18.8 ±7.6 min/2327.9 ±975.5 cGy/cm2; p < 0.001). Procedure duration was shorter in group 1 (82.9 ±18.8 min vs. 101.2 ±19.6 min, p < 0.001 and 99.8 ±20.8 min, NS). Contrast injection was necessary in 2 patients in group 1, in 8 patients in group 2 and in all patients in group 3. Because nMARQ is a thermocool catheter, the volume of fluid injection was significantly greater (2348.5 ±543.5 ml vs. 1077.9 ±280.5 ml and 1076.5 ±375.6 ml, p < 0.001). There were no periprocedural deaths. We observed no cardiac tamponade, neurological complications and no atrioesophageal fistula during follow-up.ConclusionsThe lowest radiological exposure was observed during ablation performed with an nMARQ catheter. 3D systems reduced fluoroscopy duration and the necessity of contrast injection. The nMARQ catheter requires injection of a large volume of fluid.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.