• Arch Med Sci · Jan 2019

    Direct results of a prospective randomized study comparing ablation with the nMARQ catheter and the PVAC catheter used with and without a 3D system (MAPER 3D Study).

    • Edward Koźluk, Agnieszka Piątkowska, Dariusz Rodkiewicz, Michał Peller, Janusz Kochanowski, and Grzegorz Opolski.
    • 1 Chair and Department of Cardiology, Medical University of Warsaw, Warsaw, Poland.
    • Arch Med Sci. 2019 Jan 1; 15 (1): 78-85.

    IntroductionOur aim was to compare in a prospective randomized study the safety, direct results and periprocedural data of ablation using an nMARQ catheter, a PVAC catheter used with the EnSite system, or a PVAC catheter only under fluoroscopy control.Material And MethodsOne hundred two patients (70 male, 57 ±11 years) with atrial fibrillation (AF) were prospectively randomized to: group 1 - ablation performed with an nMARQ catheter and the CARTO 3 system; group 2 - a PVAC catheter used with the EnSite system; group 3 - ablation with a PVAC catheter without a 3D system.ResultsComplete isolation of 400/402 pulmonary veins (PV) (99.5%). Linear ablation was performed in 23 patients in group 1 (small distance between lines isolating PV), in 3 patients in group 2, in 1 patient in group 3. The superior vena cava was isolated in 1 patient, 9 patients, and 9 patients respectively. Duration of fluoroscopy and dose area product were significantly smaller in group 1 (6.5 ±2.9 min/808.8 ±393.9 cGy/cm2 vs. 13.6 ±5.6 min/1662.6 ±677.8 cGy/cm2 and 18.8 ±7.6 min/2327.9 ±975.5 cGy/cm2; p < 0.001). Procedure duration was shorter in group 1 (82.9 ±18.8 min vs. 101.2 ±19.6 min, p < 0.001 and 99.8 ±20.8 min, NS). Contrast injection was necessary in 2 patients in group 1, in 8 patients in group 2 and in all patients in group 3. Because nMARQ is a thermocool catheter, the volume of fluid injection was significantly greater (2348.5 ±543.5 ml vs. 1077.9 ±280.5 ml and 1076.5 ±375.6 ml, p < 0.001). There were no periprocedural deaths. We observed no cardiac tamponade, neurological complications and no atrioesophageal fistula during follow-up.ConclusionsThe lowest radiological exposure was observed during ablation performed with an nMARQ catheter. 3D systems reduced fluoroscopy duration and the necessity of contrast injection. The nMARQ catheter requires injection of a large volume of fluid.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…