• Ann Fr Anesth Reanim · Apr 2000

    [Fiberoptic bronchoscopy during noninvasive positive-pressure ventilation in patients with chronic obstructive lung disease with hypoxemia and hypercapnia].

    • M Da Conceiçao, G Genco, J C Favier, I Bidallier, and R Pitti.
    • Département d'anesthésie-réanimation-urgences, HIA Legouest, Metz-Armées, France.
    • Ann Fr Anesth Reanim. 2000 Apr 1;19(4):231-6.

    ObjectivesTo assess the feasibility and safety of non invasive positive-pressure ventilation (NIPPV) via a face mask to performing fiberoptic bronchoscopy (FOB) in patients with COPD contraindicating FOB in spontaneous ventilation.Study DesignClinical, prospective, open, non comparative trial of feasibility.PatientsTen consecutive COPD patients (71 +/- 5 year-old, PaO2 = 53 +/- 13 mmHg and PaCO2 = 67 +/- 11 mmHg), without any sign of acute respiratory failure, admitted to the intensive care unit for pneumonia requiring a bronchoalveolar lavage (BAL). Including were: PaO2 < 70 mmHg despite nasal O2 delivered at 3 L.min-1, PaCO2 > 50 mmHg, improvement of SpO2 with NIPPV before FOB.MethodsTopical anaesthesia of the nose and pharynx was obtained with a 5% lidocaine spray. NIPPV was administered using a ventilatory support system Evita 4 (Dräger) applied through a full facial mask secured to the patient with elastic straps. Patients were first allowed to acclimate for 5 min with NIPPV (IPAP = 16 cmH2O, EPAP = 0 and trigger of 0.3 cm H2O while a FIO2 kept at 0.7). A T-adapter Medisize (Péters) was attached to the facial mask. The tip of the FOB was inserted through the nose. Topical anaesthesia of the vocal cords was obtained with 1% lidocaine solution (3 mL). The FOB was inserted into the trachea up to a bronchial sub-segment. BAL was performed by instillation of 100 mL of saline solution. After FOB, the NIPPV was maintained for 5 min. Heart rate, SpO2 were measured continuously and arterial pressure at 2 min intervals. Arterial blood gas values were obtained just prior NIPPV and after 15 min and 60 min NIPPV disconnection.ResultsFOB duration was 11 +/- 4 min. SpO2 significantly improved during FOB (from de 91 +/- 4.7% to 97% +/- 1.7) without decrease of oxygen saturation lower than 90%. There were no changes in PaCO2 and PaO2 during the hour following the end of procedure. FOB under NIPPV was performed in all patients without complications and was very well tolerated in eight patients. After NPPV disconnecting, one patient required again NIPPV for 15 min. No patient required endotracheal intubation within 24 hours. All patients survived.ConclusionApplication of NIPPV during FOB is a safe technic for maintaining adequate gas exchange in hypoxaemic and hypercapnic COPD patients not in acute respiratory failure. After the end of the procedure a close surveillance in the intensive care unit is essential.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.