    BackgroundOver the past two decades, high false alarm (FA) rates have remained an important yet unresolved concern in the Intensive Care Unit (ICU). High FA rates lead to desensitization of the attending staff to such warnings, with associated slowing in response times and detrimental decreases in the quality of care for the patient. False arrhythmia alarms are commonly due to single channel ECG artifacts and low voltage signals, and therefore it is likely that the FA rates may be reduced if information from other independent signals is used to form a more robust hypothesis of the alarm's etiology.MethodsA large multi-parameter ICU database (PhysioNet's MIMIC II database) was used to investigate the frequency of five categories of false critical ("red" or "life-threatening") ECG arrhythmia alarms produced by a commercial ICU monitoring system, namely: asystole, extreme bradycardia, extreme tachycardia, ventricular tachycardia and ventricular fibrillation/tachycardia. Non-critical ("yellow") arrhythmia alarms were not considered in this study. Multiple expert reviews of 5386 critical ECG arrhythmia alarms from a total of 447 adult patient records in the MIMIC II database were made using the associated 41,301 h of simultaneous ECG and arterial blood pressure (ABP) waveforms. An algorithm to suppress false critical ECG arrhythmia alarms using morphological and timing information derived from the ABP signal was then tested.ResultsAn average of 42.7% of the critical ECG arrhythmia alarms were found to be false, with each of the five alarm categories having FA rates between 23.1% and 90.7%. The FA suppression algorithm was able to suppress 59.7% of the false alarms, with FA reduction rates as high as 93.5% for asystole and 81.0% for extreme bradycardia. FA reduction rates were lowest for extreme tachycardia (63.7%) and ventricular-related alarms (58.2% for ventricular fibrillation/tachycardia and 33.0% for ventricular tachycardia). True alarm (TA) reduction rates were all 0%, except for ventricular tachycardia alarms (9.4%).ConclusionsThe FA suppression algorithm reduced the incidence of false critical ECG arrhythmia alarms from 42.7% to 17.2%, where simultaneous ECG and ABP data were available. The present algorithm demonstrated the potential of data fusion to reduce false ECG arrhythmia alarms in a clinical setting, but the non-zero TA reduction rate for ventricular tachycardia indicates the need for further refinement of the suppression strategy. To avoid suppressing any true alarms, the algorithm could be implemented for all alarms except ventricular tachycardia. Under these conditions the FA rate would be reduced from 42.7% to 22.7%. This implementation of the algorithm should be considered for prospective clinical evaluation. The public availability of a real-world ICU database of multi-parameter physiologic waveforms, together with their associated annotated alarms is a new and valuable research resource for algorithm developers.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…