• Critical care medicine · Sep 1993

    Decreasing imposed work of the breathing apparatus to zero using pressure-support ventilation.

    • M J Banner, R R Kirby, P B Blanch, and A J Layon.
    • Department of Anesthesiology, University of Florida, Gainesville.
    • Crit. Care Med. 1993 Sep 1;21(9):1333-8.

    ObjectivesTo apply pressure-support ventilation with the goal of decreasing the imposed work of the breathing apparatus (endotracheal tube, breathing circuit tubing, and the ventilator's demand-flow system) to zero and to evaluate a clinical method of measuring the imposed work of breathing.DesignA prospective evaluation of adult and pediatric patients receiving mechanical ventilatory support.SettingA surgical and a pediatric intensive care unit in a university hospital.PatientsFifteen patients (11 adult and four pediatric), who were diagnosed with acute respiratory failure from various etiologies, and who were intubated and spontaneously breathing, received continuous positive airway pressure and pressure-support ventilation.Measurements And Main ResultsImposed work of the breathing apparatus was calculated by integrating pressure measured at the tracheal end of the endotracheal tube from a narrow air-filled catheter and the change in volume from a miniature pneumotachograph (flow sensor) positioned between the "Y" piece of the breathing circuit and the endotracheal tube. Pressure and volume signals were directed to a computerized, portable respiratory monitor (Bicore Monitoring Systems) that provides real-time display of the pressure-volume (work) loops and calculation of the imposed work. Imposed work was measured at 0 cm H2O pressure-support ventilation, and then incremental levels of pressure-support ventilation were applied until the imposed work decreased to zero. Imposed work decreased in a quadratic fashion after incremental levels of pressure-support ventilation (r = -.83 [r2 = .69]; p < .001). At pressure-support ventilation level of 0 cm H2O, the imposed work was 0.60 +/- 0.17 joule/L. At mean pressure-support ventilation levels of 13.5 +/- 4.8 cm H2O, imposed work decreased to 0 joule/L.ConclusionsIdeally, the imposed work of the breathing apparatus should be zero to decrease the afterload on the ventilatory muscles and, thus, the patient's work of breathing. Eliminating the imposed work is achieved using appropriate levels of pressure-support ventilation. We describe an easily applied, practical method of measuring imposed work using a commercially available, portable, bedside respiratory monitor. We recommend that all patients diagnosed with respiratory failure and compromised pulmonary mechanics and who are intubated and breathing spontaneously, receive at least a minimal level of pressure-support ventilation that results in zero breathing apparatus-imposed work of breathing.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…