• J Trauma Acute Care Surg · Dec 2012

    Multicenter Study Clinical Trial

    Using micropower impulse radar technology to screen for pneumothorax: an international bi-institutional study.

    • Gwendolyn M van der Wilden, Gwen Van der Wilden, Christoph E Albers, Christof Albers, Pascal C Haefeli, Peter Haefeli, Heinz Zimmermann, Heinz Zimmerman, Aristomenis Exadaktylos, Aris Exadaktylos, Phillip Levy, Oscar Birkhan, Oscar Birkham, Maria Michaildou, Maria Michailidou, Antonios Sideris, George C Velmahos, George Velmahos, Hasan B Alam, Hasan Alam, David R King, David King, Peter J Fagenholz, Peter Fagenholz, D Dante Yeh, Dante Yeh, and Marc A de Moya.
    • Division of Trauma, Emergency Surgery and Surgical Critical Care, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts, USA.
    • J Trauma Acute Care Surg. 2012 Dec 1;73(6):1418-20.

    BackgroundPneumothoraces (PTXs) are a common entity in thoracic trauma. Micropower impulse radar (MIR) has been able to detect PTXs in surgical patients. However, this technology has not been tested previously on trauma patients. The purpose of this study was to determine the sensitivity and specificity of MIR to detect clinically significant PTXs. We hypothesized that MIR technology can effectively screen trauma patients for clinically significant PTXs.MethodsThis was a prospective observational study in Level I trauma centers in Boston, Massachusetts, and Bern, Switzerland. All trauma patients undergoing a chest computed tomographic (CT) scan were eligible for the study. Consent was obtained, and readings were performed within 30 minutes before or after the CT scan. The patients had eight lung fields tested (four on each side). The qualitative and quantitative MIR results were blinded and stored on the device. We then compared the results of the MIR to the CT scan and the need for chest tube drainage. We defined PTXs as clinically significant if they required a chest tube.ResultsSeventy-five patients were enrolled, with a mean age of 46 ± 16 years. Eighty-four percent were male. The screening test took approximately 1 minute. All but two patients had blunt chest trauma. Six true-positives, 6 false-positives, 63 true-negatives, and 0 false-negatives resulted in an overall sensitivity of 100%.ConclusionMIR is an easy to use handheld technology that effectively screened patients for clinically significant PTXs, with a sensitivity and negative predictive value of 100%. MIR may be used for rapid, repeatable, and ongoing surveillance of trauma patients.Level Of EvidenceDiagnostic study, level III.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…