-
- Junko Yamaguchi, Kosaku Kinoshita, Toru Hosokawa, and Shingo Ihara.
- Division of Emergency and Critical Care Medicine, Department of Acute Medicine, Nihon University School of Medicine, Tokyo, Japan.
- Medicine (Baltimore). 2023 May 12; 102 (19): e33768e33768.
RationaleAltered autonomic responses can be observed in patients in the intensive care unit (ICU), and these changes in abnormal autonomic responses are known to be associated with patient prognosis. Therefore, it is important to monitor autonomic nervous system activity in these critically ill patients. While the utility of monitoring critically ill patients using heart rate (HR) variability measurements has been reported, portable automated pupillometers are small, lightweight, and easy-to-operate medical devices that may be more easily evaluated for autonomic nervous system function.Patient ConcernsAn unconscious 80-year-old female patient with chronic obstructive pulmonary disease was brought to the medical emergency department after a call from her caregiver.DiagnosisOn arrival, the patient's Glasgow coma scale score was 7, her blood pressure was 140/80 mm Hg, her HR was 114 bpm, and her respiratory rate was 27 breaths/minutes with increased breathing effort. Oxygen saturation was 90% on a venturi mask (3 L of supplemental oxygen). The arterial blood gas analysis showed a pH of 7.196, a partial pressure of carbon dioxide (CO2) of 89.6 mm Hg, a partial pressure of oxygen of 87.5 mm Hg, and a bicarbonate level of 29.4 mmol/L. Other than CO2 narcosis, there were no abnormal findings to induce impaired consciousness. The patient did not respond to support with a bag-valve mask and was intubated. One hour after intubation, her impaired consciousness improved. The patient was extubated 20 hours later and discharged on Day 3.InterventionsThe patient was admitted to the ICU after being intubated, where vital signs and blood gas analysis were monitored every 2 hours, and consciousness was assessed using the Glasgow coma scale. Using a portable automated pupillometer (NeurOptics NPi™-200, Neuroptics Inc., Irvine, CA), pupillary responses, including pupil size or light reflex, were measured every 2 hours during ICU stay.OutcomesChanges in respiratory rate and partial pressure of CO2 values correlated with pupil size and constriction velocity, but HR changes were contrary.LessonsPupillary responses exhibited by automated pupillometers observed in patients with CO2 narcosis may be linked to vital signs and allow for autonomic evaluation.Copyright © 2023 the Author(s). Published by Wolters Kluwer Health, Inc.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.