• Nutrition · Oct 2023

    Differences in bioimpedance-derived fluid status between two versions of the Body Composition Monitor.

    • Sebastian Mussnig, Michael Schmiedecker, Maximilian Waller, Janosch Niknam, Christopher Paschen, Daniel Schneditz, Manfred Hecking, and Simon Krenn.
    • Division of Nephrology and Dialysis, Department of Medicine III, Medical University of Vienna, Vienna, Austria.
    • Nutrition. 2023 Oct 1; 114: 112131112131.

    ObjectivesThe Body Composition Monitor (BCM) (Fresenius Medical Care) measures body impedances in alternating currents to subsequently calculate fat and lean tissue mass, fluid compartments, and overhydration (OH). The aim of this study was to investigate differences between two versions of the BCM (an older version, 3.2.5, and a newer version, 3.3.3).MethodsBetween September 2021 and December 2021, 28 hemodialysis patients were included to undergo BCM measurements before each of 14 consecutive dialysis sessions with versions 3.2.5 and 3.3.3 devices. Measurements were performed according to instructions provided by the manufacturer. Differences between BCM devices were tested for statistical significance using paired Wilcoxon tests, neglecting clustering.ResultsA total of 288 measurement pairs of 27 patients were left after exclusion of 43 flawed data points. The mean difference in OH between both BCM devices was 0.548 L (higher for version 3.2.5). Analysis of impedance data revealed differences in the high-frequency spectrum, quantifiable by the intracellular resistance, Ri (median Ri version 3.2.5 = 1750.3 Ω; Ri version 3.3.3 = 1612.45 Ω; P < 0.001), and the time delay, Td (median Td version 3.2.5 = 1.85 ns; Td version 3.3.3 = 8.88 nanoseconds; P < 0.001).ConclusionsThis study finds that results between the two versions of the BCM differed in a clinically meaningful fashion and that the newer version 3.3.3 device had a bias toward less OH. Circulating BCM devices should be checked for versions and only devices of the same version should be used for each patient to ensure better within-patient consistency.Copyright © 2023 Elsevier Inc. All rights reserved.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…