• Critical care medicine · Oct 1999

    Comparative Study

    Cardiac output can be reliably measured noninvasively after coronary artery bypass grafting operation.

    • T Kööbi, S Kaukinen, and V M Turjanmaa.
    • Department of Clinical Physiology, Tampere University Hospital, University of Tampere, Finland.
    • Crit. Care Med. 1999 Oct 1;27(10):2206-11.

    ObjectiveTo evaluate the reliability of whole-body impedance cardiography in the measurement of cardiac output after coronary artery bypass grafting operation in comparison with the thermodilution method.DesignProspective, consecutive sampling.PatientsA total of 82 patients undergoing coronary artery bypass surgery were investigated. In a group of 41 patients who were intubated, cardiac output measurements were taken simultaneously with whole-body impedance cardiography and the thermodilution method within the first 3 hrs after the operation (early intensive care unit [ICU] period). In another group of 41 patients, the measurements were taken before the operation and in the second 12 hrs after cardiac surgery (late ICU period).InterventionsNone.Measurements And Main ResultsThe agreement between the thermodilution and whole-body impedance cardiography cardiac output measurements was good before the operation, bias 0.04 +/- 1.64 L/min (n = 41), and in the late ICU period, bias 0.00 +/- 1.84 L/min (+/-2 SD) (n = 41). The results were within 20% in 81%-85% of the cases. The agreement was satisfactory in the early ICU period, bias 0.38 +/- 2.74 L/min (n = 41). It was presumed that thermal instability of the patients was one possible source of measurement errors in the thermodilution method, causing reduced agreement between the methods in this period. The repeatability values (rv = 2.83 x SDs) for whole-body impedance cardiography were 0.44 L/min before the operation, 0.30 L/min in the early ICU period, and 0.65 L/min in the late ICU period, being significantly better than for the thermodilution method (0.79, 0.51, and 1.11 L/min, respectively) in all phases of the investigation (p < .001). The agreement between the thermodilution method and whole-body impedance cardiography is similar to reported comparisons between invasive methods in analogous settings.ConclusionsWhole-body impedance cardiography reliably measures cardiac output in patients after coronary artery bypass grafting operation. The excellent repeatability of whole-body impedance cardiography enhances the value of the method in continuous monitoring of patients after the operation.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…