-
Observational Study
The influence of pupil diameter upon and subjective quality of vision following implantable collamer lens (ICL V4c) implantation: An observational study.
- Qing Zhang, Yi Wu, He Huang, Guanghao Qin, Liangzhe Li, Jiayan Chen, Huixin Che, Ling Xu, Jonathan E Moore, Wei He, Sile Yu, Emmanuel Eric Pazo, and Xingru He.
- He Eye Specialist Hospital, Shenyang, China.
- Medicine (Baltimore). 2023 Oct 6; 102 (40): e35198e35198.
AbstractThis study aimed to assess the change in pupil size and its influence on subjective quality of vision (QoV) in subjects with implanted collamer lenses (ICLs). This retrospective study assessed 53 participants (53 eyes) implanted with ICL (V4c) and categorized them into incremental groups according to pupil diameter. Preoperative and postoperative photopic and mesopic pupil diameter, uncorrected distance visual acuity (UDVA), and QoV questionnaire scores were assessed and compared. Postoperatively, at 3 months, UDVA was -0.10 ± 0.06 logarithm of the minimum angle of resolution (LogMAR), and mean QoV for day and night was 9.34 ± 0.76 and 8.58 ± 1.29, respectively. The mean mesopic and photopic pupil diameters were 6.59 ± 0.79 mm and 4.61 ± 0.74 mm, respectively. Photopic pupil diameter negatively correlated with "QoV day" (Rs = -0.413, P = .001), positively correlated with "haloes" (Rs = 0.568*, P < .001) and "blurred vision" (Rs = 0.243, P = .04) respectively. Mesopic pupil diameter negatively correlated with "QoV night" (Rs = -0.426, P = .001), positively correlated with "haloes" (Rs = 0.624*, P < .001), "starburst" (Rs = 0.233, P = .046) and "difficulty focusing" (Rs = 0.27, P = .025), respectively. Participants had excellent VA at 3-month follow-up. Photopic and mesonic pupil diameter negatively correlated with QoV day and QoV night scores, respectively. Pupil diameter was found to have a more significant effect on visual symptoms at night, and lower QoV due to larger pupil size was more noticeable at night. Further investigation is needed to explore the importance of pupil diameter and its impact on the QoV in ICL implanted patients.Copyright © 2023 the Author(s). Published by Wolters Kluwer Health, Inc.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.