• Medicine · Oct 2023

    Evaluation of brachial plexus stiffness in different arm and head positions by sonoelastography.

    • Muhammet Ahmet Karakaya, Kamil Darcin, Ilker Ince, Yilmaz Yenigun, Kamber Kasali, and Aysenur Dostbil.
    • Department of Anesthesiology and Reanimation, Koc University Hospital, Istanbul, Turkey.
    • Medicine (Baltimore). 2023 Oct 13; 102 (41): e35559e35559.

    AbstractIntraoperative positioning-related nerve injuries, particularly those affecting the brachial plexus, are concerning complications believed to arise from stretching and/or compression of peripheral nerves. Although sonoelastography, a new ultrasound technology, is emerging as a valuable tool in the musculoskeletal system, its utility in evaluating peripheral nerves remains unclear. This study aimed to utilize sonoelastography to assess the brachial plexus during surgery, specifically investigating changes in its stiffness values in relation to different head and arm positions. In this prospective cohort study, bilateral brachial plexuses of 8 volunteers in 3 different positions were enrolled. Using a high-frequency linear probe, the stiffness of the brachial plexus was quantitatively measured in kilopascals (kPa) under 3 different positions: neutral, head rotated, and head rotated with arm hyperabducted. Intra-class agreement was evaluated. The stiffness of the brachial plexus was 7.39 kPa in the neutral position (NP), 10.28 kPa with head rotation, and 17.24 kPa when the head was turned, and the ipsilateral arm was hyperabducted. Significant increases were observed in stiffness values when the head was turned, whether ipsilaterally or contralaterally, and during hyperabduction of the arm while the head was turned (for all P < .001). Strong intra-class correlations were found for the measurements of stiffness values (ICC = 0.988-0.989; P < .001; Cronbach Alpha = 0.987-0.989). Sonoelastography revealed significant increases in the stiffness of the brachial plexus with various head rotations and arm positions compared to the neutral state. These findings suggest that sonoelastography could potentially serve as a valuable tool for assessing the risk of brachial plexus injury during surgery and for guiding optimal patient positioning. Further research with larger sample sizes is needed to establish definitive clinical applications.Copyright © 2023 the Author(s). Published by Wolters Kluwer Health, Inc.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…