- Mário Kuhn Adames, Arthur Paiva Grimaldi Santos, Murilo Romancini Daleffe, Ana Bárbara Krummenauer Formenton, Otávio Pinto, and Carlos Rodrigo de Mello Roesler.
- Homero de Miranda Gomes Regional Hospital, São José, and Adames Central Medic(CMA), Florianópolis, SC, Brazil. Electronic address: pefloripa@aol.com.
- Injury. 2023 Dec 1; 54 (12): 111134111134.
BackgroundThe biomechanical assessment of tendon repair is essential for the evaluation of different tendon suturing techniques. The shoelace suture technique with absorbable Vicryl® is a modified technique of Achilles tendon repair that may have biomechanical advantages depending on the number of threads used and the direction of the suture.PurposeTo evaluate the creep under constant pre-load, the stiffness, the maximum strength, and the failure mode for three different configurations of the shoelace suture in a bovine tendon biomechanical model.Study DesignControlled Laboratory Study.Methods36 bovine Achilles tendon specimens were acquired and divided into three test groups of 12 Achilles tendons each. A model of the calcaneal tendon rupture was created through a transverse cut with a scalpel, performed 5 centimeters proximal to the calcaneal bone insertion. Group 1 was repaired using the simple shoelace technique with just one suture. Group 2 was repaired using the shoelace technique with three sutures individually sutured from distal to proximal at the site of rupture. Group 3 was repaired using the shoelace technique with three sutures individually sutured from proximal to distal at the site of rupture.ResultsSystem creep after constant pre-load was 5.9 ± 2.5 mm, 3.0 ± 0.4 mm and 2.9 ± 0.4 mm for groups 1, 2 and 3, respectively. The system's stiffness was 23.2 ± 2.8 N/mm, 30.3 ± 1.1 N/mm and 29.8 ± 2.3 N/mm for groups 1, 2 and 3, respectively. In the final load-to-failure test, the ultimate load force (ULF) was 158.2 ± 27.5 N, 346.5 ± 47.6 N and 358.1 ± 41.6 N for groups 1, 2 and 3, respectively. There was statistical significance in the comparative tests between groups 1-2 and 1-3 in terms of means of creep, system stiffness and maximum system strength. No statistically significant difference was found between groups 2 and 3 when analyzing creep, system stiffness and ULF. Suture breakage was the prevalent mode of failure for all tested groups.ConclusionThe shoelace with three sutures significantly reduced creep in the preloading phase and increased the stiffness and ultimate load force. The biomechanical results demonstrate better overall mechanical performance of the technique than the simple shoelace technique. The better mechanical performance indicates that the shoelace with three sutures could result in early postoperative rehabilitation.Clinical RelevanceThis study indicates that the shoelace suture technique with three sutures is biomechanically strong and stiff, being a possible therapeutic option to be used.Copyright © 2023 Elsevier Ltd. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.