- Héctor J Aguado, Juan Mingo-Robinet, Virginia García-Virto, Iñigo SanJose-Pardo, Sergio Pais, Begoña A Álvarez-Ramos, Clarisa Simón-Pérez, and David C Noriega.
- Orthopaedic and Traumatology Department, Hospital Clínico Universitario, Valladolid, Spain. Electronic address: hjaguado@gmail.com.
- Injury. 2023 Dec 1; 54 Suppl 7: 111043111043.
IntroductionThe incidence of osteoporotic distal humeral fractures (DHF) is on the rise. Their operative management is demanding. Fixation with non-locking reconstruction plates was associate with a high number of complications. Elbow arthroplasty (total or hemi) has been proposed as an alternative treatment, in spite of lifetime activity restrictions, and risk of complications, unknown implant survival and problematic revision surgery. Precontoured anatomical locking plates have increased the strength of the fixation in complex fractures.Hypothesisdouble plating ORIF with precontoured anatomical locking plates is a safe and reliable treatment option for the management of AO/OTA type C3 DHF in patients aged 75 and older.Patients And MethodsA retrospective case series study of patients aged 75 years old and older with an AO/OTA type C3 DHF treated with ORIF with double precontoured anatomical locking plates between 2007 and 2021. Pathologic fractures were excluded. Patients' demographic, surgical, clinical, and radiological data were reviewed.ResultsA total of 27 women and 3 men, mean age of 80.1 years (range 75-93 years), were included. Mean Charlson index was 5 (range 3-8). Out of 30 patients, 19 had already died. Mean survival time after the surgical treatment was 72.3 months. Mean Mayo elbow performance score was 88.9 (range 60-100); 23 patients scored excellent or good. All fractures healed with no cases of delay union or non-union, hardware failure or loss of reduction. No patient needed a revision surgery to arthroplasty. The total number of complications was 12 (40%), mainly ulnar neuropathy (5) and cerclage removal (4).ConclusionORIF with double pre-contoured locking plates may be a safe and reliable treatment for type C3 DHF in patients aged 75 years and older, with a good functional outcome. Complications are expected but not related to loss of reduction, fixation failure or revision to elbow arthroplasty.Copyright © 2023 Elsevier Ltd. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.